BCM400y500x1K8A31
300
250
200
150
100
50
0
0.0 3.5 7.0 10.5 14.0 17.5 21.0 24.5 28.0 31.5 35.0
Load Current (A)
VIN:
400 V
Figure 10 — VRIPPLE vs. IOUT ; No external COUT. Board mounted
Figure 11 — Full load ripple, 2.2 µF CIN; No external COUT. Board
module, scope setting : 20 MHz analog BW
mounted module, scope setting : 20 MHz analog BW
Figure 13 — 35 A – 0 A transient response:
Figure 12 — 0 A– 35 A transient response:
CIN = 2.2 µF, no external COUT
CIN = 2.2 µF, no external COUT
Figure 15 — Start up from application of EN with pre-applied
Figure 14 — Start up from application of VIN = 400 V, 50% IOUT
,
VIN = 400 V, 50% IOUT, 100% COUT
100% COUT
BCM® Bus Converter
Rev 1.3
05/2015
vicorpower.com
800 927.9474
Page 13 of 23