BCM384x120y300Azz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted;
boldface
specifications apply over the temperature range of
-40°C
≤
T
CASE
≤
100°C (T-Grade); all other specifications are at T
CASE
= 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Protection
Input overvoltage lockout threshold
Input overvoltage recovery threshold
Input overvoltage lockout hysteresis
Overvoltage lockout response time
Fault recovery time
Input undervoltage lockout
threshold
Input undervoltage recovery
threshold
Input undervoltage lockout
hysteresis
Undervoltage lockout response time
Output overcurrent trip threshold
Output overcurrent response time
constant
Short circuit protection trip threshold
Short circuit protection response time
Thermal shutdown threshold
V
IN_OVLO+
V
IN_OVLO-
V
IN_OVLO_HYST
T
OVLO
T
AUTO_RESTART
V
IN_UVLO-
V
IN_UVLO+
V
IN_UVLO_HYST
T
UVLO
I
OCP
T
OCP
I
SCP
T
SCP
T
J_OTP
125
Effective internal RC filter
45
1
28.2
380
220.0
230.0
400.0
9
47
440
240.0
255.0
15
47
36
5.2
50
500
259.0
290.0
430.0
V
V
V
µs
ms
V
V
V
µs
A
ms
A
µs
°C
BCM
®
Bus Converter
Page 5 of 21
Rev 1.5
08/2016
vicorpower.com
800 927.9474