 浏览型号BCM3814V60E15A3T06的Datasheet PDF文件第6页浏览型号BCM3814V60E15A3T06的Datasheet PDF文件第7页浏览型号BCM3814V60E15A3T06的Datasheet PDF文件第8页浏览型号BCM3814V60E15A3T06的Datasheet PDF文件第9页浏览型号BCM3814V60E15A3T06的Datasheet PDF文件第11页浏览型号BCM3814V60E15A3T06的Datasheet PDF文件第12页浏览型号BCM3814V60E15A3T06的Datasheet PDF文件第13页浏览型号BCM3814V60E15A3T06的Datasheet PDF文件第14页  
BCM3814x60E15A3yzz  
PMBus™ Reported Characteristics  
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of  
–40°C TCASE 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.  
Monitored Telemetry  
• The current telemetry is only available in forward operation. The input and output current reported value is not supported in reverse operation.  
ACCURACY  
(RATED RANGE)  
FUNCTIONAL  
REPORTING RANGE  
UPDATE  
RATE  
ATTRIBUTE  
REPORTED UNITS  
PMBus™ READ COMMAND  
(88h) READ_VIN  
HI Side Voltage  
HI Side Current  
LO Side Voltage [d]  
LO Side Current  
LO Side Resistance  
Temperature [e]  
5% (LL – HL)  
28 to 66V  
–1 to 44A  
100µs  
100µs  
100µs  
100µs  
100ms  
100ms  
VACTUAL = VREPORTED x 10–1  
IACTUAL = IREPORTED x 10–2  
VACTUAL = VREPORTED x 10–1  
IACTUAL = IREPORTED x 10–2  
RACTUAL = RREPORTED x 10–5  
TACTUAL = TREPORTED  
20% (10 – 20% of FL)  
5% (20 – 133% of FL)  
(89h) READ_IIN  
(8Bh) READ_VOUT  
5% (LL – HL)  
7.0 to 16.55V  
–4 to 176A  
20% (10 – 20% of FL)  
5% (20 – 133% of FL)  
(8Ch) READ_IOUT  
5% (50 – 100% of FL) at NL  
10% (50 – 100% of FL) (LL – HL)  
(D4h) READ_ROUT  
500 to 3000µΩ  
–55 to 130ºC  
(8Dh) READ_TEMPERATURE_1  
7°C (Full Range)  
[d] Default READ LO Side Voltage returned when unit is disabled = –300V.  
[e] Default READ Temperature returned when unit is disabled = –273°C.  
Variable Parameters  
• Factory setting of all Thresholds and Warning limits listed below are 100% of specified protection values.  
• Variables can be written only when module is disabled with VHI < VHI_UVLO– and external bias (VDDB) applied.  
• Module must remain in a disabled mode for 3ms after any changes to the variables below to allow sufficient time to commit changes to EEPROM.  
FUNCTIONAL  
REPORTING  
RANGE  
ACCURACY  
(RATED RANGE)  
DEFAULT  
ATTRIBUTE  
PMBusTM COMMAND  
CONDITIONS / NOTES  
VALUE  
100%  
100%  
100%  
100%  
100%  
100%  
100%  
0ms  
HI Side Overvoltage  
Protection Limit  
VHI_OVLO– is automatically 3%  
lower than this set point  
(55h) VIN_OV_FAULT_LIMIT  
(57h) VIN_OV_WARN_LIMIT  
(D7h) DISABLE_FAULTS  
(5Bh) IIN_OC_FAULT_LIMIT  
(5Dh) IIN_OC_WARN_LIMIT  
(4Fh) OT_FAULT_LIMIT  
5% (LL – HL)  
5% (LL – HL)  
5% (LL – HL)  
28 – 66V  
28 – 66V  
14 – 36V  
0 – 44A  
HI Side Overvoltage  
Warning Limit  
HI Side Undervoltage  
Protection Limit  
Can only be disabled to a preset  
default value  
HI Side Overcurrent  
Protection Limit  
20% (10 – 20% of FL)  
5% (20 – 133% of FL)  
HI Side Overcurrent  
Warning Limit  
20% (10 – 20% of FL)  
5% (20 – 133% of FL)  
0 – 44A  
Overtemperature  
Protection Limit  
Internal temperature  
Internal temperature  
7°C (Full Range)  
7°C (Full Range)  
50µs  
0 – 125°C  
0 – 125°C  
0 – 100ms  
Overtemperature  
Warning Limit  
(51h) OT_WARN_LIMIT  
(60h) TON_DELAY  
Additional time delay to the  
undervoltage start-up delay  
Turn On Delay  
BCM® in a VIA Package  
Page 10 of 41  
Rev 2.0  
02/2018