 浏览型号BCM330F110T300B00的Datasheet PDF文件第6页浏览型号BCM330F110T300B00的Datasheet PDF文件第7页浏览型号BCM330F110T300B00的Datasheet PDF文件第8页浏览型号BCM330F110T300B00的Datasheet PDF文件第9页浏览型号BCM330F110T300B00的Datasheet PDF文件第11页浏览型号BCM330F110T300B00的Datasheet PDF文件第12页浏览型号BCM330F110T300B00的Datasheet PDF文件第13页浏览型号BCM330F110T300B00的Datasheet PDF文件第14页  
BCM352x110y300B00  
7.0 USING THE CONTROL SIGNALS PC, TM  
Primary Control (PC) pin can be used to accomplish the  
following functions:  
• Logic enable and disable for module: Once Ton1 time has  
been satisfied, a PC voltage greater than VPC_EN will cause  
the module to start. Bringing PC lower than VPC_DIS will  
cause the module to enter standby.  
• Auxiliary voltage source: Once enabled in regular  
operational conditions (no fault), each BCM module  
PC provides a regulated 5 V, 3.5 mA voltage source.  
• Synchronized start up: In an array of parallel modules, PC  
pins should be connected to synchronize start up across  
units. This permits the maximum load and capacitance  
to scale by the number of paralleled modules.  
• Output disable: PC pin can be actively pulled down in order  
to disable the module. Pull down impedance shall be lower  
than 60 Ω.  
• Fault detection flag: The PC 5 V voltage source is internally  
turned off as soon as a fault is detected.  
• Note that PC can not sink significant current during a fault  
condition. The PC pin of a faulted module will not cause  
interconnected PC pins of other modules to be disabled.  
Temperature Monitor (TM) pin provides a voltage  
proportional to the absolute temperature of the converter  
control IC.  
It can be used to accomplish the following functions:  
• Monitor the control IC temperature: The temperature in  
Kelvin is equal to the voltage on the TM pin scaled  
by 100. (i.e. 3.0 V = 300 K = 27 ºC). If a heat sink is applied,  
TM can be used to protect the system thermally.  
• Fault detection flag: The TM voltage source is internally  
turned off as soon as a fault is detected. For system  
monitoring purposes microcontroller interface faults are  
detected on falling edges of TM signal.  