AIM1714xB6MC7D5yzz
Environmental Qualification
Testing Activity
High Temperature Operating Bias/Life
(HTOB/HTOL)
Temperature Cycling Test (TCT)
Temperature Humidity Bias (THB)
High Temperature Storage (HTS)
Low Temperature Storage (LTS)
Reference Standard
JESD22-A108D
IPC-9592B
JESD22-A101C
JESD22-A103D
JESD22–A119
Test Details
1000hrs. Nominal Full Load at Max operating temperature
125˚C to -40˚C, 700 cycles
1000hrs. Nominal Input voltage, Minimal load 85˚C,
85% RH
1000hrs. 125˚C
1000hrs. -65˚C
Method 514.6, Procedure I, Category 24, 20-2000Hz,
@7.7g
RMS
, 1hour /axis for 3 axis. Product mounted on an
evaluation board, nominal line 50% load.
Method 516.5, Procedure I, Functional shock 40G, total
of 18 shocks. Product mounted on an evaluation board,
nominal Line 50% load.
Low and high temperature tests, rapid thermal cycling,
random vibration testing, combined stress testing and
destruct testing.
Method 215K, 3 minutes exposure
Class 1C (HBM) Minimum
Class II (CDM) Minimum
Random Vibration
MIL-STD-810G
Mechanical Shock
MIL-STD-810G
Highly Accelerated Life Test (HALT)
Internal Vicor Procedure - DP-0265
Res. Solvents
ESD Human Body Model
ESD Charged Device Model
MIL-STD-202G
JEDEC JS-001-2012
JESD22-C101E
AIM™ in a VIA Package
Page 9 of 14
Rev 1.2
08/2017