Figure 1
VI BRICK AC Front End
Evaluation Board layout and
dimensional drawing,
component side.
(Click on drawing to view larger.)
Basic Specifications and Operating Limits
Please use the following table for operating limits:
Table 1
Operating Limits
Description
Input Range
Output voltage
Output Power
Operating temperature
Output capacitance
Specification
85 – 264 Vac
48 Vdc
330 W Over entire input range
-40 to 100 °C
6,000 to 12,000μF
Notes
Universal input
Partially Regulated, SELV
Case temperature
63V rating
Please refer to Figure 1 for locations of the input and output connections as viewed
from the component side. Wires may be soldered directly to the pads instead of ring
lugs if desired to minimize circuit impedances.
vicorpower.com
Applications Engineering: 800 735.6200
Rev 1.2