C5310
VCXO
RF output
Parameter
Signal
Min
40
Typ
HCMOS
15.0
Max.
Units
Condition
Ordering Code5
RFH
Load
pF
ns
%
Rise and Fall time
Duty cycle
Signal
5
60
@ 15 pF 10 to 90 %
@ Vs/2
PECL
50
RFP
RFL
RFS
Load
Ω
ns
%
Vs - 2V
Rise and Fall time
Duty cycle
Signal
1
55
20 to 80 %
45
LVDS
100
Load
Ω
ns
%
Rise and Fall time
Duty cycle
Signal
Load
Output Power
1
60
10 to 90 %
40
-3
Sinewave
50
0
Ω
dBm
3
Frequency Tuning (EFC)
Parameter
Tuning Range
Min
±75.0
±100.0
Typ
±90.0
±140.0
Max.
+200.0
±200.0
10
Units
ppm
ppm
%
Condition
Frequency > 40MHz
Frequency <40MHz
Linearity
Tuning Slope
Positive
Control Voltage Range
0.0
0.5
10
1.65
2.5
3.3
4.5
VDC
VDC
k Ω
with Vs=3.3VDC
with Vs=5.0VDC
Frequency control input impedance
Additional parameters
Parameter
Min
Typ
Max.
Units
Condition
Phase Noise
-85
dBc/Hz
10 Hz
100 Hz
1 kHz
@52 MHz
HCMOS
3,3V
-115
-138
-153
-155
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
10 kHz
100 kHz
Jitter
Phase Noise
0,3
-80
ps RMS
dBc/Hz
@ 12 kHz to 20 MHz
10 Hz
100 Hz
1 kHz
@155,52 MHz
-105
-135
-143
-143
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
PECL
3,3V
10 kHz
100 kHz
Jitter
Phase Noise
0,6
-80
ps RMS
dBc/Hz
@ 12 kHz to 20 MHz
10 Hz
100 Hz
1 kHz
@155,52 MHz
-112
-130
-150
-155
0,2
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
ps RMS
LVDS
3,3V
10 kHz
100 kHz
Jitter
@ 12 kHz to 20 MHz
v.2007-03-09 · page 2 of 6
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju Road,
WaiGaoQiao Free Trade Zone, Pudong,
Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
+86 21 5048 1881 fax