C4650
OCXO
Additional parameters
Parameter
Min
Typ
Max.
-95
-125
-145
-150
-155
Units
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
g
Condition
1 Hz
10 Hz
100 Hz
1 kHz
Phase Noise3
at 10Mhz
10 kHz
Weight
53
Processing & Packing
Handling & processing note
Absolute Maximum Ratings
Parameter
Min
Typ
Max.
Units
Condition
Supply voltage (Vs)
28
V
Output Load
50
25
+85
+125
pF
Ohms
°C
with HCMOS signal
with Sinewave signal
Operable temperature range
Storage temperature range
-55
-55
°C
How to Order this Product:
Step 1 Use this worksheet to forward the following information to your factory representative:
Model
Stability Code
Supply Voltage Code
RF Output Code
Package Code
Frequency
C4650
Example: C4650
C509
SV120
RFH
A1
10Mhz
Step 2 The factory representative will then respond with a Vectron Model Number in the following configuration:
Model
Package Code
Dash
Dash Number
[Factory Generated 4 digit number]
C4650
[Customer Specified Package Code]
-
Typical P/N = C4650A1-0001
Notes:
1
2
Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies.
Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control
voltage, load, temperature (25°C)
3
4
5
Phase noise degrades with increasing output frequency.
Subject to technical modification.
Contact factory for availability.
Vectron International · www.vectron.com
v.2005-07-14 · page 3 of 3
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+86 21 28909740 tel.
+86 21 28909240 fax
+-1 717-486-3411 tel
+-1 717-486-5920 fax