C1310
PXO
RF output
Parameter
Signal
Min
Typ
HCMOS
Max.
Units
Condition
Ordering Code5
RFH
Load
15.0
pF
Rise and Fall time
Duty cycle
Signal
5
60
ns
%
@ 15 pF 10 to 90 %
40
45
@ Vs/2
PECL
50
RFP
RFL
Load
Ω
ns
%
Vs - 2V
20 to 80 %
Rise and Fall time
Duty cycle
Signal
Load
Rise and Fall time
Duty cycle
1
55
LVDS
100
Ω
ns
%
1
60
10 to 90 %
40
Additional parameters
Parameter
Min
Typ
Max.
Units
Condition
Phase Noise
-75
dBc/Hz
10 Hz
@155 MHz
PECL
-110
-135
-142
-142
1
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
100 Hz
1 kHz
3,3V
10 kHz
100 kHz
Jitter
Weight
ps RMS
g
@ 10 kHz to 20 MHz
2
Processing & Packing
handling&processing note
Enclosures
Type G223A
for HCMOS and LVHCMOS Version
Type G218B
for PECL; LVPECL and LVDS Version
Package Codes:
Code
A1
Height “H”
5,9
Pin Length “L”
NA
Code
B1
Height “H”
5,9
Pin Length “L”
NA
Dimensions: mm
Dimensions: mm
v.2005-11-09 · page 2 of 5
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju Road,
WaiGaoQiao Free Trade Zone, Pudong,
Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
+86 21 5048 1881 fax