S-Band 6-bit Phase Shifter
CHP1102-98F
Peak Phase Error (PPE) definition
PPE(i) = measured_Phase(S21)@state(i) - measured_Phase(S21)@state(0) -
theoreticalPhaseValue@State(i)
Amplitude Variation (Av) definition
Av(i) = Measured_dB(S21)@state(i) - Measured_dB(S21)@state(0)
RMS Peak Phase Error (RMS_PPE) definition
63
(PPE(i) PPE)2
i0
RMS_PPE =
64
63
PPE(i)
i0
Where PPE
64
RMS Amplitude variation (RMS_Av) definition
63
Av(i)
i0
RMS _ AV Av
64
Amplitude variation standart deviation (StdDev_Av) definition
63
1
StdDev_Av = 20log 1
. (1 Av(i) _lin)2 (dB)
64
i0
Av (i)
20
The translation of Av(i) from dB to linear is given by: Av(i)_lin = 10
(i) is in the range [0:63]
Absolute Maximum Ratings (1)
Tamb.= +25°C
Symbol
V+
Parameter
Maximum DC positive supply
Values
+6
Unit
V
V-
Maximum DC negative supply
Phase shifter control voltage (Vlow Vhigh)
Maximum peak input power overdrive
Operating temperature range
-6
V
Vctrl
Pin
-0.5 +5.5
+11
V
dBm
°C
°C
Top
Tstg
-40 to +85
-55 to +150
Storage temperature range
(1) Operation of this device above anyone of these parameters may cause permanent
damage.
Ref. : DSCHP11022305 - 31 Oct 12
3/10
Specifications subject to change without notice
Bât. Charmille - Parc SILIC - 10, Avenue du Québec - 91140 VILLEBON-SUR-YVETTE - France
Tel.: +33 (0) 1 69 86 32 00 - Fax: +33 (0) 1 69 86 34 34