TEC 3 Series, 3 Watt  
Output Specifications (continued)  
Capacitive load  
– Single output  
3.3 Vout models: 4400 µF max.  
5.0 Vout models: 2200 µF max.  
9.0 Vout models: 1300 µF max.  
12 Vout models: 1000 µF max.  
15 Vout models: 820 µF max.  
24 Vout models: 470 µF max.  
– Dual output  
5.0 Vout models: 1200 µF max. (each output)  
12 Vout models: 520 µF max. (each output)  
15 Vout models: 440 µF max. (each output)  
General Specifications  
Temperature ranges  
– Operating (natural convection: 20 LFM, 0.1 m/s)  
– Case temperature  
–40°C to +90°C  
+105°C max.  
– Storage temperature  
–55°C to +125°C  
Derating  
3.4%/K above 75°C  
5 – 95 % rel H max.  
1‘600 VDC  
Humidity (non condensing)  
Isolation voltage  
– I/O isolation voltage (60 s)  
Isolation resistance (input/output)  
1 GOhm min.  
Isolation capacitance (input/output)  
50 pF max.  
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign)  
Switching frequency  
5‘124‘000 h  
100 kHz min. (pulse frequency modulation)  
MIL-STD-810F  
Shock, vibration and thermal shock  
Remote On/Off  
– On:  
– Off:  
– Off idle current:  
open circuit or high impedance  
2 – 4 mA current applied via 1kOhm resistor  
2.5 mA typ.  
Safety standards  
– Desinged to meet (no certification)  
IEC/EN/UL 62368-1, UL 60950-1  
Environmental compliance – Reach  
www.tracopower.com/products/reach-declaration.pdf  
RoHS directive 2011/65/EU  
– RoHS  
Physical Specifications  
Casing material  
non-conducting black plastic  
Silicone (UL 94V-0 rated)  
tinned copper  
Potting material  
Pin material  
Package weight  
4.5 g (0.16 oz)  
Soldering profile  
260°C / 10 s max. (wave soldering)  
Supporting Documents: www.tracopower.com/overview/tec3  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
www.tracopower.com  