TEC 3 Series, 3 Watt  
Input Specifications  
Input current at no load  
9 Vin models: 55 mA typ.  
12 Vin models: 30 mA typ.  
24 Vin models: 12 mA typ.  
48 Vin models: 8 mA typ.  
Surge voltage (1 s max.)  
Start up voltage  
9 Vin models: 15 V max.  
12 Vin models: 25 V max.  
24 Vin models: 50 V max.  
48 Vin models: 100 V max.  
9 Vin models: 4.5 V (or lower)  
12 Vin models: 9 V (or lower)  
24 Vin models: 18 V (or lower)  
48 Vin models: 36 V (or lower)  
Under voltage shut down  
9 Vin models: 2 - 4 V  
12 Vin models: 6 - 8 V  
24 Vin models: 13 - 17 V  
48 Vin models: 29 - 35 V  
Input filter  
internal capacitor  
Recommended input fuse  
9 Vin models: 1.6 A (slow blow type)  
12 Vin models: 0.8 A (slow blow type)  
24 Vin models: 0.5 A (slow blow type)  
48 Vin models: 0.315 A (slow blow type)  
Conducted noise  
EMC immunity  
EN 55032 class A or B with external components  
www.tracopower.com/overview/tec3  
Application note for filter class A/B proposal  
– ESD (electrostatic discharge)  
EN 61000-4-2, air 8 kV, contact 6 kV,  
perf. criteria A  
– Radiated immunity  
– Fast transient / surge  
(with external input capacitor)  
EN 61000-4-3, 10 V/m, perf. criteria A  
EN 61000-4-4, 2 kV, perf. criteria A  
EN 61000-4-5, 1 kV perf. criteria A  
all models: Nippon chemi-con KY 220µF/100V  
EN 61000-4-6, 10 Vrms, perf. criteria A  
EN 61000-4-8  
– Conducted immunity  
– Magnetic field immunity  
100 A/m, continuous, perf. criteria A  
1000 A/m, 1 sec., perf. criteria A  
Output Specifications  
Voltage set accuracy  
1 % max.  
Regulation  
– Input variation (Vin min. to Vin max.)  
0.2 % max.  
– Load variation (0 – 100 %)  
– Load variation (10 – 90 %)  
– Cross regulation  
single output: 1 % max.  
dual output: 1 % max. (balanced load)  
single output: 0.5 % max.  
dual output: 0.8 % max. (balanced load)  
dual output: 5 % max. (asymmetrical load 25 % / 100 %)  
Temperature coefficient  
0.02 %/K max.  
Ripple and noise (20 MHz Bandwidth)  
Current limitation  
75 mVp-p typ.  
140 - 240 % of Iout max.  
continuous, automatic recovery  
Short circuit protection  
Start up time  
(constant resistive load)  
– Power ON  
– Remote ON  
10 ms typ. / 20 ms max.  
10 ms typ. / 20 ms max.  
Transient response time (25% load step change)  
500 μs typ.  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
www.tracopower.com  
Page 2 of 4