DC/DC Converters
TDR 3 Series
3 Watt
General Specifications
Temperature ranges
– Operating
– Storage
– Case temperature
–40°C to +85°C
–55°C to +125°C
tba.
Load derating
3.3 %/K above +70°C
5 % to 90 % rel. H max.
acc. MIL-STD-810F
acc. MIL-STD-810F
>2.4 Mio h
Humidity (non condensing)
Thermal shock
Vibration
Reliability, calculated MTBF (MIL-HDBK-217F, at+25°C, ground benign)
Isolation voltage (60 sec.) – Input/Output
1500 VDC
Isolation capacitance
Isolation resistance
– Input/Output
50 pF max.
– Input/Output (500 VDC)
>10 GOhm
Altitude during operation
tba.
Safety standard (designed to meet)
IEC/EN 60950-1, UL 60950-1
Safety approvals
Switching frequency
Remote On/Off
– UL/cUL
www.ul.com -> certifications -> File e188913
100 kHz (PWM)
– On:
– Off:
open or high impedance
2...4 mA current applied via 1KOhm resistor
2.5 mA max.
– Off stand by input current
EMC Consideration
L1
Recommended filter for
EN 55022 class A compliance
+Vin
-Vin
+Vout
TDR 3
dc/dc-converter
C1
-Vout
C3
Input models C1
C3
L1
value
order code
TCK-047
TCK-062
datasheet
5 VDC
4.7 µF / 25 V 1812 MLCC
6.8 µF / 50 V 1812 MLCC
10 µH
12 µH
10 µH
10 µH
www.tracopower.com/products/tck047.pdf
www.tracopower.com/products/tck062.pdf
12 VDC
24 VDC
48 VDC
220pF / 3 kV 1808 MLCC
4.7 µF / 50 V 1812 MLCC
4.7 µF / 100 V 1812 MLCC
TCK-047
www.tracopower.com/products/tck047.pdf
L1
Recommended filter for
+Vin
+Vout
EN 55022 class B compliance
TDR 3
dc/dc-converter
C1
C2
-Vin
-Vout
C3
Input models C1 & C2
C3
L1
value
order code
(SMD type)
datasheet
5 VDC
6.8 µF / 25 V 1812 MLCC
10 µH
12 µH
18 µH
18 µH
TCK-047
TCK-062
TCK-046
TCK-046
www.tracopower.com/products/tck047.pdf
www.tracopower.com/products/tck062.pdf
12 VDC
24 VDC
48 VDC
4.7 µF / 50 V 1812 MLCC
4.7 µF / 100 V 1812 MLCC
220pF / 3 kV 1808 MLCC
www.tracopower.com/products/tck046.pdf
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 3 of 4