DC/DC Converters  
TDR 2 Series  
2 Watt  
General Specifications  
Temperature ranges  
– Operating  
– Storage  
–40°C to +85°C (with no derating)  
–55°C to +125°C  
Humidity (non condensing)  
Thermal shock  
5 % to 90 % rel. H max.  
acc. MIL-STD-810F  
acc. MIL-STD-810F  
>2.8 Mio h  
Vibration  
Reliability, calculated MTTF (MIL-HDBK-217F, @ +25°C, ground benign)  
Isolation voltage (60 sec.) Input/Output  
1500 VDC  
Isolation capacity  
Isolation resistance  
Input/Output  
50 pF max.  
Input/Output (500 VDC)  
>10 GOhm  
Safety standard (designed to meet)  
IEC/EN 60950-1, UL 60950-1  
100 kHz (PWM)  
open or high impedance  
Switching frequency  
Remote On/Off  
On:  
Off:  
2...4 mA current applied via 1KOhm resistor  
2.5 mA max.  
Off stand by input current  
EMC Consideration  
L1  
Recommended filter for  
EN 55022 class A compliance  
+Vin  
-Vin  
+Vout  
TDR 2  
dc/dc-converter  
C1  
-Vout  
C3  
Input models C1  
C3  
L1  
value  
order code  
(SMD type)  
datasheet  
5 VDC  
10 µF / 25 V 1812 MLCC  
6.8 µF / 50 V 1812 MLCC  
2.2 µH  
18 µH  
TCK-059  
www.tracopower.com/products/tck059.pdf  
12 VDC  
24 VDC  
48 VDC  
220pF / 3 kV 1808 MLCC  
4.7 µF / 50 V 1812 MLCC  
4.7 µF / 100 V 1812 MLCC  
TCK-046  
www.tracopower.com/products/tck046.pdf  
L1  
Recommended filter for  
EN 55022 class B compliance  
+Vin  
+Vout  
TDR 2  
dc/dc-converter  
C1  
C2  
-Vin  
-Vout  
C3  
Input models C1 & C2  
C3  
L1  
value  
order code  
(SMD type)  
datasheet  
5 VDC  
10 µF / 25 V 1812 MLCC  
2.2 µH  
18 µH  
27 µH  
18 µH  
TCK-059  
TCK-046  
TCK-063  
TCK-046  
www.tracopower.com/products/tck059.pdf  
www.tracopower.com/products/tck046.pdf  
www.tracopower.com/products/tck063.pdf  
www.tracopower.com/products/tck046.pdf  
12 VDC  
24 VDC  
48 VDC  
2.2 µF / 50 V 1812 MLCC  
2.2 µF / 100 V 1812 MLCC  
220pF / 3 kV 1808 MLCC  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
http://www.tracopower.com  
Page 3 of 4