Industrial DC/DC-Converter
TCL-DC Series
24 to 60 Watt
Input Specifications
Input power at no load
1.0 Watt max.
Start-up voltage/under voltage shut down
TCL 012 model: 8.4 VDC / 7.6 VDC
TCL 024 & TCL 060 models: 17.2 VDC / 15.7 VDC
Reverse polarity protection
Efficiency
by internal fuse
86 % typ.
Output Specifications
Output voltage adj. range
5 VDC model: 5.0 – 5.25 VDC
12 VDC models: 12.0 – 15.0 VDC
24 VDC models: 24.0 – 28.0 VDC
Regulation
– Input variation Vin min. to Vin max.
– Load variation 0...100%
0.5 % max
0.5 % max
Ripple and noise (20 MHz bandwidth)
<50 mV pk-pk
Electronic short circuit protection
current limitation at 110 % typ.
(constant current, automatic recovery)
Overvoltage protection, trigger point
5 VDC model: <6.5 V
12 VDC models: <24 V
24 VDC models: <42 V
General Specifications
Temperature ranges
– Operating
–25°C to +70°C max.
– Storage (non operating)
–25°C to +85°C
1.5 %/K above +50°C
95 % rel. H max.
0.02 %/K
Temperature derating
Humidity (non condensing)
Temperature coefficient
Switching frequency
55 – 180 kHz depending on load
(frequency modulation)
Isolation voltage (60 sec.) – Input/Output
1500 VDC
>2.5 Mio h
Reliability, calculated MTBF at +25°C (according to IEC 61709)
Safety standards
– Information technology equipment
IEC 60950-1, EN 60950-1 (output SELV),
UL Std. 60950-1 (2nd Edition) +Am1:2011,
CAN/CSA-C22.2 No. 60950-1-07 +Am1:2011
– Industrial control equipment
– Electronic equipment for power installation
– Electrical equipment for machines
UL 508
EN 50178
EN 60204
Safety approvals
– CB test certificate (IEC 60950-1)
– UL approval
www.tracopower.com/products/tcl-cb.pdf
www.ul.com -> certifications
UL 508C listed, CSA C22.2 No.14 File e210002
UL 60950-1, CSA 60950-1-03
– CSA certification
www.tracopower.com/products/tcl-csa.pdf
www.tracopower.com/products/tcl060dc_gs.pdf
– GS certification
Electromagnetic compatibility (EMC), emissions
– Conducted RI suppression on input
– Radiated RI suppression
EN 61000-6-3
EN 55022 class B
EN 55022 class B
Electromagnetic compatibility (EMC), immunity
EN 61000-6-2
– Electrostatic discharge (ESD)
– Radiated RF field immunity
EN 61000-4-2 4 kV / 8 kV
EN 61000-4-3 10 V/m
EN 61000-4-4 Level 3
EN 61000-4-5 Level 3
EN 61000-4-6 10 Vrms
– Electrical fast transient / burst immunity
– Surge immunity
– Immunity to conducted RF disturbances
Environmental compliance – Reach
– RoHS
www.tracopower.com/products/reach-declaration.pdf
RoHS directive 2011/65/EU
Case protection
Enclosure material
Mounting
IP 20 (IEC 60529)
plastic UL 94V-0 rated
DIN-rails as per EN 50022-35x15/7.5
(snap-on with self-locking spring)
bracket for wall/chassis mount included
Installation instructions
www.tracopower.com/products/tcl-dc-inst.pdf
All specifications valid at nominal input voltage, full load and +25 °C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3