ELECTRICAL SPECIFICATIONS (continued)
VDD = +2.7V to +5.25V; VREF = 2.5V External/internal reference unless otherwise noted; fSCLK = 2 MHz;
TA = TMIN to TMAX, unless otherwise noted.
Parameter
A Version1
B Version1
Unit
Test Conditions/Comments
POWER REQUIREMENTS
VDD
+2.7/+5.25
+2.7/+5.25
V (min/max)
IDD
Normal Mode4 (PM Mode 2)
Static
700
850
700
450
120
12
700
850
700
450
120
12
μA (max)
μA (typ)
Internal reference enabled
Internal reference disabled
fSAMPLE = 50 ksps
fSAMPLE = 10 ksps
fSAMPLE = 1 ksps
VDD = 2.7V to 5.25V
VDD = 2.7V to 3.6V
VDD = 4.75V to 5.25V
VDD = 5 V
Operational (fSAMPLE = 125 kSPS)
Using Standby Mode (PM Mode 4)
μA (typ)
μA (typ)
μA (typ)
Using Shutdown Mode
(PM Modes 1 and 3)
Standby Mode5
μA (typ)
210
1
210
1
μA (max)
μA (max)
μA (max)
mW (max)
mW (max)
μW (max)
μW (max)
mW (max)
μW (max)
Shutdown Mode5
2
2
3.5
2.1
5
3.5
2.1
5
Normal Mode Power Dissipation
Shutdown Power Dissipation
Standby Power Dissipation
VDD = 3 V
VDD = 5 V
3
3
VDD = 3 V
1.05
630
1.05
630
VDD = 5 V
VDD = 3 V
Note 1: The TSA7887’s temperature range is –40°C to +125°C for both A and B versions.
Note 2: SNR calculation includes distortion and noise components.
Note 3: Sample tested at TA = 25°C to ensure compliance.
Note 4: All digital inputs at GND except for CS at VDD. All digital outputs are unloaded. Analog inputs are connected to GND.
Note 5: SCLK is at GND when SCLK is off. All digital inputs are at GND except for CS at VDD. All digital outputs are unloaded. Analog inputs
are connected to GND.