TS3001  
TS3001 Start-up Time  
APPLICATIONS INFORMATION  
As the TS3001 is powered up, its FOUT terminal  
(and PWMOUT terminal, if enabled) is active once  
the applied VDD is higher than 0.9 volt. Once the  
applied VDD is higher than 0.9 volt, the master  
oscillator achieves steady-state operation within  
1.2ms.  
Minimizing Power Consumption  
To keep the TS3001’s power consumption low,  
resistive loads at the FOUT and PWMOUT terminals  
increase dc power consumption and therefore should  
be as large as possible. Capacitive loads at the  
FOUT and PWMOUT terminals increase the  
TS3001’s transient power consumption and, as well,  
should be as small as possible.  
Current- and Voltage-Controlled Oscillators  
The TS3001  
can  
be  
configured  
into  
a
Current-Controlled Oscillator as shown in Figure 2.  
One challenge to minimizing the TS3001’s transient  
power consumption is the probe capacitance of  
oscilloscopes and frequency counter instruments.  
Most instruments exhibit an input capacitance of  
15pF or more. Unless buffered, the increase in  
transient load current can be as much as 400nA.  
To minimize capacitive loading, the technique shown  
in Figure 1 can be used. In this circuit, the principle of  
series-connected capacitors can be used to reduce  
the effective capacitive load at the TS3001’s FOUT  
and PWMOUT terminals.  
Figure 2: Configuring the TS3001 into a  
Current-Controlled Oscillator.  
With a current source sourcing a current of 223nA to  
262nA, FOUT can generate an output signal with a  
frequency range of 5.2kHz to 90kHz. In a similar  
manner, a Voltage-Controlled Oscillator can be  
configured as shown in Figure 3. In this case, a  
voltage source sourcing a voltage of 290mV to  
341mV can generate an FOUT output signal  
frequency range of 5.2kHz to 90kHz as well. It is  
recommended to use resistor values with a 1%  
tolerance.  
Figure 1: Using an External Capacitor in Series with  
Probes Reduces Effective Capacitive Load.  
To determine the optimal value for CEXT once the  
probe capacitance is known by simply solving for  
CEXT using the following expression:  
1
CꢁꢄT=  
1
1  
 
CLOAꢅ(ꢁFF) CPROꢇꢁ  
For example, if the instrument’s input probe  
capacitance is 15pF and the desired effective load  
capacitance at either or both FOUT and PWMOUT  
terminals is to be 5pF, then the value of CEXT should  
be ≤7.5pF.  
Figure 3: Configuring the TS3001 into a  
Voltage-Controlled Oscillator.  
Page 8  
TS3001DS r1p0  
RTFDS