DC/DC Converters
THL 25 Series
25 Watt
Input Specifications
Input current at no load (at nominal input voltage)
12 Vin models: 80 mA typ.
24 Vin models: 55 mA typ.
48 Vin models: 40 mA typ.
Recommended input fuse (slow blow)
Start-up voltage
12 Vin models: 5000 mA
24 Vin models: 2500 mA
48 Vin models: 1250 mA
12 Vin models: 9 VDC (or lower)
24 Vin models: 18 VDC (or lower)
48 Vin models: 36 VDC (or lower)
Surge voltage (0.1 sec. max.)
Reflected input ripple current
Conducted noise (input)
12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
12 Vin models: 80 mAp-p typ.
24 Vin models: 50 mAp-p typ.
48 Vin models: 30 mAp-p typ.
EN 55022 class A with external L/C
EN 55022 class B with external filter
see application note
ESD (electrostatic discharge)
EN 61000-4-2, air 8 kV, contact 6 kV,
perf. criteria A
Radiated immunity
EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / surge (with external input capacitor)
EN 61000-4-4, 2 kV, perf. criteria A
EN 61000-4-5, 1 kV perf. criteria A
external input capacitor:
Nippon chemi-con KY 220 µF, 100 V, ESR 48 mOhm
Conducted immunity
EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy
1 %
Output voltage adj. range
10 % for single output models only.
Trim up via resistor between Trim and -Vout
Trim down via resistor between Trim and +Vout
resistor values see application note
Regulation
– Input variation (Vmin – Vmax)
– Load variation
0.2 % max.
single output models: 0.2 % max. (0 – 100 % load)
dual output models: 1.0 % max. (0 – 100 % balanced load)
dual output models: 5.0 % max. (25 – 100 % asymmetrical load)
–Cross regulation
Minimum load
not required
Ripple and noise (20 MHz bandwidth)
3.3 & 5.0 VDC models: 100 mVp-p typ.
12 & 15 VDC models: 150 mVp-p typ.
Temperature coefficient
Output current limitation
Short circuit protection
Over voltage protection
Transient response setting time
Max. capacitive load
0.02 %/K
at 150 % of Iout max., hiccup
indefinite, automatic recovery
shutdown at +20% of nominal output
250 µs typ. (25% load step change)
3.3 VDC models: 10’300 µF
5 VDC models: 6’800 µF
12 VDC models: 1’200 µF
15 VDC models: 750 µF
12 VDC models: 680 µF (each output)
15 VDC models: 380 µF (each output)
http://www.tracopower.com
Page 2 of 4