MKW10M SERIES  
Total Power International, Inc.  
DC/DC CONVERTER 10W, Reinforced Insulation, Medical Safety  
Test Setup  
Input Reflected-Ripple Current Test Setup  
Input reflected-ripple current is measured with a inductor Lin (4.7µH) and Cin (220µF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets  
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.  
To Oscilloscope  
+Vin  
+Out  
+
+
Lin  
DC / DC  
Converter  
Current  
Probe  
Load  
Battery  
Cin  
-Vin  
-Out  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.47µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load  
between 50 mm and 75 mm from the DC/DC Converter.  
Copper Strip  
Cout  
+Vin  
+Out  
Copper Strip  
+Vin  
+Out  
Com.  
-Out  
Scope  
Scope  
Single Output  
DC / DC  
Converter  
Dual Output  
DC / DC  
Converter  
Resistive  
Load  
Resistive  
Load  
Cout  
Scope  
Copper Strip  
Cout  
-Vin  
-Out  
Copper Strip  
-Vin  
Copper Strip  
Technical Notes  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In  
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. By using a  
good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 10µF for the 12V input devices and a 4.7µF for the 24V input devices and a  
2.2µF for the 48V devices, capacitor mounted close to the power module helps ensure stability of the unit.  
+
+Vin  
+Out  
+
DC / DC  
Converter  
DC Power  
Source  
Load  
Cin  
-
-Vin  
-Out  
Output Ripple Reduction  
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is  
recommended to use 3.3µF capacitors at the output.  
+
+Vin  
-Vin  
+Out  
+
+Vin  
+Out  
Com.  
-Out  
Single Output  
DC / DC  
Converter  
Load  
Load  
Dual Output  
DC / DC  
Converter  
DC Power  
Source  
Cout  
Cout  
DC Power  
Source  
Cout  
Load  
-
-Out  
-
-Vin  
Maximum Capacitive Load  
The MKW10M series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up,  
affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data  
sheet.  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the  
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95. The derating curves are determined  
from measurements obtained in a test setup.  
Position of air velocity  
probe and thermocouple  
Air Flow  
50mm / 2in  
15mm / 0.6in  
DUT  