MJWI10 SERIES
DC/DC CONVERTER 10W, High Power Density
Total Power International, Inc.
Output Specifications
Parameter
Conditions
At 50% Load and Nominal Vin
Dual Output, Balanced Loads
Vin=Min. to Max.
Min.
Typ.
---
Max.
±2.0
±2.0
±1.0
---
Unit
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
---
%Vnom.
---
±1.0
±0.3
±0.5
%
%
%
---
Load Regulation
Io=0% to 100%
---
Min.Load
No minimum Load Requirement
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
---
60
300
±3
100
600
±6
mV p-p
μsec
%
---
25% Load Step Change
Foldback
---
---
±0.01
150
±0.02
---
%/℃
%
110
Continuous
General Specifications
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF(calculated)
Conditions
60 Seconds
500 VDC
Min.
1500
1000
---
Typ.
---
Max.
---
Unit
VDC
MΩ
---
---
100KHz, 1V
---
1500
---
pF
---
450
---
KHz
Hours
MIL-HDBK-217F@25℃, Ground Benign
350,000
---
Safety Approvals
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Input Fuse
24V Input Models
2000mA Slow-Blow Type
48V Input Models
1000mA Slow-Blow Type
Remote On/Off Control
Parameter
Conditions
Min.
Typ.
Max.
Unit
Converter On
Converter Off
2.5V ~ 50V or Open Circuit
0~1.0V or Short Circuit (Pin 2 and Pin 6)
Control Input Current (on)
Control Input Current (off)
Control Common
Vctrl = 5V
Vctrl = 0V
---
---
---
500
μA
μA
---
Referenced to Negative Input
---
-500
Standby Input Current
---
10
mA
Environmental Specifications
Parameter
Conditions
Min.
-40
---
Max.
Unit
℃
℃
℃
% rel. H
Operating Ambient Temperature Range (See Power Derating Curve)
Natural Convection
+80
+100
+125
95
Case Temperature
Storage Temperature Range
-50
---
Humidity (non condensing)
Cooling
Free-Air convection
Six-Sided Shielded, Metal Case
---
RFI
Lead Temperature (1.5mm from case for 10Sec.)
260
℃
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com