MIWI06 SERIES
DC/DC CONVERTER 6W, DIP-Package
Total Power International, Inc.
Output Specifications
Parameter
Conditions
Min.
---
Typ.
±1.0
±1.0
±0.1
±0.6
Max.
±2.0
±2.0
±0.5
±1.2
Unit
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Dual Output, Balanced Loads
Vin=Min. to Max.
---
%
---
%
Load Regulation
Io=0% to 100%
---
%
Min.Load
No minimum Load Requirement
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
---
---
50
---
80
100
600
---
mV P-P
mV P-P
uS
Over Line, Load & Temp.
25% Load Step Change
---
300
±3
---
%
---
±0.01
150
±0.02
---
%/℃
%
Foldback
110
Continuous
General Specifications
Parameter
Conditions
Min.
1500
3000
1000
---
Typ.
---
Max.
---
Unit
VDC
VDC
MΩ
Standard
Suffix H (note 6)
I/O Isolation Voltage (rated)
60 Seconds
---
---
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
500 VDC
---
---
100KHz, 1V
1000
330
---
---
pF
---
---
KHz
Hours
MIL-HDBK-217F@25℃, Ground Benign
800,000
---
Safety Approvals(pending)
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Input Fuse
24V Input Models
1500mA Slow-Blow Type
48V Input Models
800mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Conditions
Ambient
Min.
-40
---
Max.
+85
Unit
℃
℃
℃
+100
+125
95
Storage Temperature Range
Humidity (non condensing)
-50
---
% rel. H
Cooling
Free-Air convection
---
Lead Temperature (1.5mm from case for 10Sec.)
260
℃
Power Derating Curve
(3.3 & 5V Output Models)
(Other Output Models)
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com