MIW4000 Series  
Model Selection Guide  
Model  
Number  
Input  
Voltage  
Output  
Voltage  
Output Current  
Input Current  
Reflected  
Ripple  
Current  
Efficiency  
Max.  
Min.  
mA  
@Max. Load  
mA (Typ.)  
@No Load  
mA (Typ.)  
@Max. Load  
% (Typ.)  
VDC  
VDC  
3.3  
5
mA  
1200  
1000  
500  
mA (Typ.)  
MIW4021  
MIW4022  
MIW4023  
MIW4024  
MIW4025  
MIW4026  
MIW4027  
MIW4031  
MIW4032  
MIW4033  
MIW4034  
MIW4035  
MIW4036  
MIW4037  
120  
100  
50  
212  
78  
81  
86  
85  
81  
86  
85  
78  
81  
86  
85  
81  
86  
85  
257  
12  
291  
24  
15  
400  
40  
294  
20  
10  
( 9 ~ 36 )  
{5  
{12  
{15  
3.3  
5
{500  
{250  
{200  
1200  
1000  
500  
{50  
{25  
{20  
120  
100  
50  
257  
291  
294  
106  
129  
12  
145  
48  
15  
400  
40  
147  
10  
10  
( 18 ~ 75 )  
{5  
{12  
{15  
{500  
{250  
{200  
{50  
{25  
{20  
123  
145  
147  
Note :  
Absolute Maximum Ratings  
Parameter  
Min.  
-0.7  
-0.7  
---  
---  
Max.  
50  
Unit  
1. Specifications typical at Ta=+25], resistive load,  
nominal input voltage, rated output current unless  
otherwise noted.  
24VDC Input Models  
48VDC Input Models  
VDC  
VDC  
]
Input Surge Voltage  
( 1000 mS )  
100  
Lead Temperature (1.5mm from case for 10 Sec.)  
Internal Power Dissipation  
260  
2. Transient recovery time is measured to within 1%  
error band for a step change in output load of 75%  
to 100%.  
2,500  
mW  
Exceeding these values can damage the module. These are not continuous  
operating ratings.  
3. Ripple & Noise measurement bandwidth is 0-20  
MHz.  
4. These power converters require a minimum output  
loading to maintain specified regulation.  
5. Operation under no-load conditions will not  
damage these devices; however they may not  
meet all listed specifications.  
Environmental Specifications  
6. All DC/DC converters should be externally fused at  
the front end for protection.  
Parameter  
Operating Temperature  
Operating Temperature  
Storage Temperature  
Humidity  
Conditions  
Ambient  
Case  
Min.  
-25  
-40  
-40  
---  
Max.  
+71  
+90  
+125  
95  
Unit  
]
]
]
%
7. Other input and output voltage may be available,  
please contact factory.  
8. Specifications subject to change without notice.  
Cooling  
Free-Air Convection  
EN55022 Class A  
Conducted EMI