MIW2100 Series
Thermal Considerations
Many conditions affect the thermal performance of the
power module, such as orientation, airflow over the module,
and board spacing. To avoid exceeding the maximum
temperature rating of the components inside the power
module, the case temperature must be kept below 90°C.
The derating curves were determined from measurements
obtained in an experimental apparatus.
Position of air velocity
Air Flow
50mm / 2in
probe and thermocouple
15mm / 0.6in
DUT
Safety according to EN 60950 / UL 1950
Insulation between adjacent primary circuits or between
primary & secondary circuits:
Operational-,Basic- and Supplementary insulation for
working voltages up to 420 VDC /300 VAC.
Reinforced insulation for working voltages up to 210 VDC /
150 VAC.
Insulation between adjacent secondary circuits:
Operatonal-,Basic- Supplementary and Reinforced
insulation for working voltages up to 420 VDC /300 VAC.
Electromagnetic emission EN 55022 < B
Conducted and radiated emissions
MIW214X-types EN 55022 < A ; with external coupling
capacitor Cio=1 nF < B