TOTAL POWER INT'L
MIW1000
Input Fus e Selection Guide
5V Input Models
12V Input Models
24V Input Models
48V Input Models
1500mA Slow - Blow Type
700mA Slow - Blow Type
350mA Slow - Blow Type
135mA Slow - Blow Type
Typical Applications
+
+Vin
+Out
+
+Vin
+Out
Fuse
DC Power
Source
Fuse
DC Power
Source
Load #1
Single Output
DC / DC
Converter
Dual Output
DC / DC
Converter
Load
Common
-Out
Load #2
-
-Vin
-Out
-
-Vin
Derating Curve
100
80
60
40
20
0
100
80
60
40
20
0
Output
Power
%
Output
Power
%
-3.3% / O
C
-25
-10
0
20
40
60
80
100
125
Ambient Temperature OC
Connecting Pin Patterns
(2.54 mm / 0.1 inch grids )
Single Output
Dual Output
NOTE:
1. Specifications typical at Ta=+ 25] ,resistive load,nominal input voltage,rated output current unless otherwise noted.
2. Transient recovery time is measured to within 1% error band for a step change in output load of 50% to 100%.
3. When measure output ripple & noise,an external 0.1uF ceramic capacitor is recommended to be placed from + Vout
to - Vout (single output) and each output to common (dual output).
4. Other input and output voltage may be available,Please contact factory.
5. Specifications subject to change without notice.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
ꢀ
Email: sales@total-power.com http://www.total-power.com
-4-
ꢀ