MIDR03M SERIES  
DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety  
Total Power International, Inc.  
Output Specifications  
Parameter  
Conditions  
Min.  
---  
Typ.  
---  
Max.  
±4.0  
±4.0  
±0.5  
Unit  
Output Voltage Setting Accuracy  
Output Voltage Balance  
Line Regulation  
At 50% Load and Nominal Vin  
Dual Output, Balanced Loads  
Vin=Min. to Max.  
%Vnom.  
---  
±2.0  
±0.3  
%
%
%
---  
Load Regulation  
Io=10% to 100%  
---  
±0.5  
±1.0  
Min.Load  
No minimum Load Requirement  
Ripple & Noise  
max. 20MHz Bandwidth  
---  
---  
30  
50  
mV P-P  
Temperature Coefficient  
Short Circuit Protection  
±0.01  
±0.02  
%/  
Continuous  
Isolation, Safety Standards  
Parameter  
Conditions  
60 Seconds  
Min.  
3000  
4500  
---  
Typ.  
---  
Max.  
---  
Unit  
VACrms  
VPK  
I/O Isolation Voltage (reinforced)  
I/O Isolation Test Voltage  
Leakage Current  
Flash tested for 1 Second  
240VAC, 60Hz  
500 VDC  
---  
---  
---  
2
μA  
I/O Isolation Resistance  
I/O Isolation Capacitance  
10  
---  
---  
GΩ  
100KHz, 1V  
---  
20  
---  
pF  
cUL/UL60950-1, CSA C22.2 No. 60950-1-03  
Safety Standards  
UL60601-1,CSA C22.2 No.601-1,  
IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition, 2 MOOP  
IEC60950-1 CB report, cUL/UL 60950-1 certificate  
UL60601-1 UL certificate  
Approvals(Pending)  
General Specifications  
Parameter  
Conditions  
Min.  
25  
Typ.  
60  
Max.  
Unit  
KHz  
Switching Frequency  
MTBF(calculated)  
---  
---  
MIL-HDBK-217F@25, Ground Benign  
1,000,000  
---  
Hours  
Input Fuse  
5V Input Models  
12V Input Models  
24V Input Models  
2000mA Slow-Blow Type  
1000mA Slow-Blow Type  
500mA Slow-Blow Type  
Environmental Specifications  
Parameter  
Conditions  
Min.  
-40  
---  
Max.  
+75  
+95  
+125  
95  
Unit  
Natural Convection  
Operating Ambient Temperature Range (See Power Derating Curve)  
Case Temperature  
-50  
---  
Storage Temperature Range  
Humidity (non condensing)  
% rel. H  
Cooling  
Free-Air convection  
---  
Lead Temperature (1.5mm from case for 10Sec.)  
260  