MDWI03 SERIES
DC/DC CONVERTER 3W, DIP Package
Total Power International, Inc.
Power Derating Curve
Notes
1
2
3
4
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
however, they may not meet all specifications listed.
5
6
7
8
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications
Mechanical Dimensions
Pin Connections
Pin
Single Output
-Vin
Dual Output
-Vin
23.8 [0.94]
1
2
7
Remote On/Off
Remote On/Off
NC
NC
NC
8
Common
+Vout
9
+Vout
-Vout
+Vin
10
16
-Vout
+Vin
[0.02]
0.5
0.5 [0.02]
NC: No Connection
2.54
3.0
12.7
2.54
[0.10]
[0.10]
[0.12]
[0.50]
1
2
7
8
Bottom View
16
10
9
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
15.24 [0.60]
23.8 [0.94]
2.54
[0.10]
X.XX±0.13 ( X.XXX±0.005)
►Pin diameter 0.5 ±0.05 (0.02±0.002)
Physical Characteristics
Case Size
Case Material
Pin Material
Weight
:
:
:
:
23.8x13.7x8.0 mm (0.94x0.54x0.31 inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
phosphor bronze
5.4g
Total Power International, Inc
Toll Free: 877-646-0900