MCWI03 SERIES  
DC/DC CONVERTER 3W, SIP-Package  
Total Power International, Inc.  
Test Setup  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.47µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between  
50 mm and 75 mm from the DC/DC Converter.  
Copper Strip  
Cout  
Copper Strip  
Cout  
+Vin  
+Out  
-Out  
+Vin  
Dual Output  
DC / DC  
Converter  
+Out  
Com.  
-Out  
Scope  
Scope  
Single Output  
DC / DC  
Converter  
Resistive  
Load  
Resistive  
Load  
Scope  
Copper Strip  
Cout  
-Vin  
-Vin  
Copper Strip  
330pF  
Copper Strip  
330pF  
Technical Notes  
Remote On/Off  
Negative logic remote on/off turns the module off during a logic high voltage on the remote on/off pin, and on during a logic low. To turn the power module on and off,  
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent.  
A logic high is 2.7V to 15V. A logic low is under 0.6 VDC or open circuit, drops down to 0VDC by 2mV/℃. The maximum sink current at on/off terminal during a logic  
low is 1 mA. The maximum allowable leakage current of the switch at on/off terminal= (under 0.6VDC or open circuit) is 1mA.  
Maximum Capacitive Load  
The MCWI03 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,  
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.  
Overcurrent Protection  
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited  
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back  
into its specified range.  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In  
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.  
Capacitor mounted close to the power module helps ensure stability of the unit, it is commended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω  
at 100 KHz) capacitor of a 3.3µF for the 12V input devices and a 1.5µF for the 24V and 48V devices.  
+
+Vin  
+Out  
+
DC / DC  
Converter  
DC Power  
Source  
Load  
Cin  
-
-Vin  
-Out  
Output Ripple Reduction  
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is  
recommended to use 3.3µF capacitors at the output.  
+
+Vin  
-Vin  
+Out  
+
+Vin  
+Out  
Single Output  
DC / DC  
Converter  
Load  
Load  
Dual Output  
DC Power  
Source  
Cout  
Cout  
DC Power  
Source  
DC / DC Com.  
Converter  
Cout  
Load  
-
-Out  
-
-Vin  
-Out  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the  
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105. The derating curves are determined from  
measurements obtained in a test setup.  
Position of air velocity  
probe and thermocouple  
Air Flow  
50mm / 2in  
15mm / 0.6in  
DUT  
Total Power International, Inc  
Toll Free: 877-646-0900  
www.total-power.com