TOTAL POWER INT'L
MBU100
Abs olute Maximum Ratings
Exceeding these values can damage the module.These are not continuous operating ratings.
Parameter
Min.
Max.
Unit.
5VDC Input Models
Input Surge Voltage
-0.7
-0.7
-0.7
---
9
VDC
VDC
VDC
mW
12VDC Input Models
18
( 1000 mS )
24VDC Input Models
30
Internal Power Dissipation
450
Environmental Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
Operating Temperature
Storage Temperature
Humidity
-25
-40
---
---
---
---
+75
+125
95
]
]
%
Cooling
Free-Air Convection
Model Selection Guide
Model
Number
Input
voltage
Output
Voltage
Output
Current
Output
Current
Input
Current
Max. Load
mA (Typ.)
Input
Load
Regulation
Efficiency
% (Typ.)
Current
No Load
mA (Typ.)
VDC
VDC
mA (Max.)
mA (Min.)
% (Max.)
MBU101
MBU102
MBU103
MBU104
MBU111
MBU112
MBU113
MBU114
MBU115
MBU116
MBU117
MBU118
5
9
200
110
84
4
2
290
260
262
258
117
107
106
105
60
11
8
7
6
9
5
5
4
8
5
4
4
69
76
77
78
71
77
79
80
70
76
79
79
5
30
13
7
(4.5 ~ 5.5)
12
15
5
1.5
1
67
200
110
84
4
12
9
2
(10.8 ~ 13.2)
12
15
5
1.5
1
67
200
110
84
4
24
9
2
54
(21.6 ~ 26.4)
12
15
1.5
1
53
67
53
Specifications typical at Ta=+ 25] ,resistive load,nominal input voltage,rated output current unless otherwise noted.
Input Specifications
Parameter
Model
Min.
Typ.
Max.
Unit
5V Input Models
12V Input Models
24V Input Models
4.5
5
12
5.5
13.2
26.4
0.3
Input Voltage Range
10.8
21.6
---
VDC
A
24
Reverse Polarity Input Current
Input Filter
---
All Models
Internal Capacitor
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
ꢀ
Email: sales@total-power.com http://www.total-power.com
-2-
ꢀ