IDS100 Series
Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
Output Current
Input Current
Efficiency
Max.
mA
Min.
mA
@Max. Load
mA (Typ.)
@No Load
mA (Typ.)
@Max. Load
% (Typ.)
VDC
VDC
5
IDS101
IDS112
IDS121
IDS122
3.3
2000
200
200
200
200
1434
21
27
92
93
83
85
( 4.75 ~ 13.6 )
12
5
3.3
5
2000
2000
2000
896
331
490
( 6 ~ 16.5 )
24
45
( 16 ~ 28 )
Notes :
Absolute Maximum Ratings
Parameter
Min.
-0.7
-0.7
-0.7
---
---
Max.
Unit
VDC
VDC
VDC
]
1. Specifications typical at Ta=+25], resistive load,
nominal input voltage, rated output current unless
otherwise noted.
5VDC Input Models
12VDC Input Models
24VDC Input Models
16
25
Input Surge Voltage
( 1000 mS )
30
2. Transient recovery time is measured to within 1%
error band for a step change in output load of 50%
to 100%.
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
235
1500
mW
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
3. Ripple & Noise measurement bandwidth is 0-20
MHz.
4. These power converters require a minimum
output loading to maintain specified regulation.
5. Operation under no-load conditions will not
damage these modules; however, they may not
meet all specifications listed.
Environmental Specifications
6. All DC/DC converters should be externally fused at
the front end for protection.
Parameter
Operating Temperature
Storage Temperature
Humidity
Conditions
Min.
-25
-25
---
Max.
+70
+125
95
Unit
]
Ambient
7. Other input and output voltage may be available,
please contact factory.
]
%
8. Specifications subject to change without notice.
Cooling
Free-Air Convection
Input Specifications
Parameter
Model
Min.
3.5
5.5
12
Typ.
---
---
---
Max.
3.9
6
Unit
Start Voltage
5V Input Models
12V Input Models
24V Input Models
VDC
15