UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC
19" COMPATIBLE EUROCARD 100 WATTS MULTIPLE OUTPUT
SWITCHING MODE POWER SUPPLIES HPU100 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC1000-3-2 HARMONIC CORRECTION
MEET UNIVERSAL SAFETY STANDARDS
19” COMPATIBLE EUROCARD FORMAT
EMI MEET EN 55022 & FCC CLASS B
CE MARKING COMPLIANCE
3U X 10HP X 160MM VMEbus STANDARD
TOTAL POWER INT'L
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Typ. 90-264Vac with PFC.
Input Connector:
DIN 41612 at rear.
Input Frequency:
47-63Hz.
Inrush Current:
Typ. <30.6A @ 230Vac.
Input Current:
1.0A @ 115Vac, 0.5A @ 230Vac.
Dielectric Withstand:
Meet IEC950.
EMI:
Meet EN 55022 & FCC B.
Power Factor Correction:
Meet Harmonic Correction
IEC1000-3-2 .PF typ. 0.97-0.98.
Power Indicator:
Green LED.
Power OK Signal:
Installed.
Logic Inhibit:
Installed.
Hold-up Time:
20mS @ 115Vac & 230Vac.
Earth Leakage:
Less than 0.40mA @ 230Vac.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Connector:
DIN 41612 at rear.
Line Regulation:
Typ. 0.5%.
Load Regulation:
Main VO1 typ. ±1-2.0%.
Aux.VO2 typ. ±2.0% (Mag. Amp.)
Aux.VO3 typ. ±3.0% (PR).
Noise & Ripple:
Typ. 1% peak to peak.
OVP:
Built-in at main VO1.
Adjustability:
Available at VO1 & VO2.
Overload Protection (OLP):
Fully protected against
output overload and short circuit.
Consult the factory for OLP setting.
Operating Temperature:
0 to +50°C full load. Derates
from +50 to +70°C by derating 2%/°C.
Storage Temperature:
-25 to +85°C.
Temperature Coefficient:
Typ. 0.04% /°C.
Cooling:
Forced air flow is recommended for Ta > +50°C
full load operation.
Construction format:
10HP(TE) X3UX160mm VMEbus
standard Eurocard format.
GENERAL SPECIFICATION
Efficiency:
Typ. 73-76%.
Switching Frequency:
Fixed frequency 83K Hz.
Circuit Topology:
Fixed frequency forward circuit.
Transient Response:
Output voltage returns in less than
3mS following a 25% load change.
Safety Standard:
IEC950/UL1950 Class I.
Power Density:
2.0 Watt / Cubic Inch.
Note:
All measurements are at nominal input, full load, and +25℃ unless otherwise specified.