XBS303V29R-G
■TYPICAL
PERFORMANCE CHARACTERISTICS
(1) Forward Current vs. Forward Voltage
(2) Reverse Current vs. Reverse Voltage
10
Ta=125℃
100
Ta=125℃
1
Reverse Current I
R
(mA)
Forward Current I
F
(A)
10
100℃
75℃
1
0.1
0.1
75℃
25℃
25℃
0.01
-25℃
0.01
0.001
0.0
0.1
0.2
0.3
0.4
0.5
0.001
0
10
20
30
Forward Voltage V
F
(V)
(3) Forward Voltage vs. Operating Temperature
Reverse Voltage V
R
(V)
(4) Reverse Current vs. Operating Temperature
0.6
100
V
R
=20V
0.4
I
F
=3A
1.5A
0.5A
0.1A
Reverse Current I
R
(mA)
Forward Voltage V
F
(V)
10
10V
1
0.1
0.2
0.01
0.0
-50
0
50
100
150
0.001
0
50
100
150
Operating Temperature Ta (℃)
Operating Temperature Ta (℃)
(5) Inter-Terminal Capacity vs. Reverse Voltage
(6) Average Forward Current vs. Operating Temperature
1000
Average Forward Current I
F(AVE)
(A)
30
Inter-Terminal Capacity Ct (pF)
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0
10
20
0
50
100
150
Reverse Voltage V
R
(V)
800
600
400
Ta=25℃
200
0
Operating Temperature Ta (℃)
3/4