XC62RP
Series
■Typical Application Circuit
GStandard
Circuit
XC62RP
V
IN
C
IN
0.1µF
(Tantalum)
V
OUT
C
L
0.1µF
(Tantalum)
V
SS
R
L
3
GNotes
on Use
Please use with a load capacitance (C
L
) of less than 0.1µF.
■Directions for use
1. Please use with a load capacitance, C
L
, of less than 0.1µF and in 0.01µF steps.
2. Since short-circuit protection is not built-in, the IC may be damaged by rush current should the output pin be connected to the Ground pin.
3. When the load capacitance, C
L
, is small, overshoot will be produced when the power is switched on.
4. As the output pin's current is only a few
µA,
output voltage will increase should output be pulled-up by means of a resistor.
■Test Circuits
Circuit 1
V
IN
V
IN
V
OUT
A
0.1µF
(Tantalum)
V
SS
0.1µF
(Tantalum)
V
Circuit 2
V
IN
V
OUT
OPEN
V
IN
V
SS
A
308