TT6061BB/TT6061BS
Preliminary
_________________________________________________________________________________
TT6061BB/TT6061BS RECOMMEND APPLICATION DIAGRAM
D1
1N40
+
-
C3
100UF/16V
AC
110V/60Hz
ZD1
6.8V
LAMP
TT6061BB/TT6061BS
TRIAC
G
T2
T1
1 CK
AT 8
VSS 7
NC 6
CI 5
10K
R4
2 FI
3VDD
C2
2.2UF/16V
TOUCH PLATE
1N4148
1N4148
2M
R3
-
4 TI
NOTE :
FOR 220V/50HZ :
CHANGE R1 330K TO 390K ( FOR 60HZ CHANGE TO 50HZ )
CHANGE R2 20K/1W TO 39K/2W ( FOR 110V CHANGE TO 220V )
CHANGE R6 1M TO 2M ( FOR 110V CHANGE TO 220V )
TC6061BB/TC6061BS RECOMMEND APPLICATION DIAGRAM
D1
1N40
+
-
C3
100UF/16V
AC
110V/60Hz
ZD1
6.8V
LAMP
TRIAC
T2
T1
G
10K
R4
C2
2.2UF/16V
TOUCH PLATE
1N4148
1N4148
2M
R3
-
NOTE :
FOR 220V/50HZ :
CHANGE R1 330K TO 390K ( FOR 60HZ CHANGE TO 50HZ )
CHANGE R2 20K/1W TO 39K/2W ( FOR 110V CHANGE TO 220V )
CHANGE R6 1M TO 2M ( FOR 110V CHANGE TO 220V )
2013/5/29
page 3 of 5
Ver 2.0