 浏览型号78Q2120C09-64CGT的Datasheet PDF文件第1页浏览型号78Q2120C09-64CGT的Datasheet PDF文件第3页浏览型号78Q2120C09-64CGT的Datasheet PDF文件第4页浏览型号78Q2120C09-64CGT的Datasheet PDF文件第5页浏览型号78Q2120C09-64CGT的Datasheet PDF文件第6页浏览型号78Q2120C09-64CGT的Datasheet PDF文件第7页浏览型号78Q2120C09-64CGT的Datasheet PDF文件第8页浏览型号78Q2120C09-64CGT的Datasheet PDF文件第9页  
78Q2120C  
10/100BASE-TX  
Transceiver  
mode of operation, a 25MHz crystal should be  
connected between the XTLP and XTLN pins.  
Alternatively, an external 25MHz clock signal can be  
connected to the CKIN pin. The chip senses activity  
on the CKIN pin, and will automatically configure itself  
to use the external clock. In this mode of operation, a  
crystal is not required and the XTLP and XTLN pins  
should be left floating or connected together.  
FUNCTIONAL DESCRIPTION  
GENERAL  
Power Management  
The 78Q2120C has three power saving modes:  
Chip Power-Down  
Receive Power Management  
Transmit High Impedance Mode  
Transmit Clock Generation  
The transmitter uses an on-chip frequency  
synthesizer to generate the transmit clock. In  
100BASE-TX operation, the synthesizer multiplies the  
reference clock by 5 to obtain the internal 125MHz  
Chip power-down is activated by setting the PWRDN  
bit in MII register MR0.11 or pulling high the PWRDN  
pin. When the chip is in the power-down mode, all  
on-chip circuitry is shut off, and the device  
consumes minimum power. While in the power-  
down state, the 78Q2120C still responds to  
management transactions.  
serial transmit clock.  
In 10BASE-T mode, it  
generates an internal 20MHz transmit clock by  
multiplying the 25MHz reference clock by 4/5. The  
synthesizer references either the local 25 MHz crystal  
oscillator, or the externally applied clock, depending  
on the selected mode of operation.  
Receive power management (RXCC mode) is  
activated by setting the RXCC bit in MII register  
MR16.0. In this mode of operation, the adaptive  
equalizer, the clock recovery phase lock loop (PLL),  
and all other receive circuitry will be powered down  
when no valid MLT-3 signal is present at the UTP  
receive line interface. As soon as a valid signal is  
detected, all circuits will automatically be powered  
up to resume normal operation. During this mode of  
operation, RX_CLK will be inactive when there is no  
data being received. Note that the RXCC mode is  
not supported during 10BASE-T operation.  
Receive Signal Qualification  
The integrated signal qualifier has separate squelch  
and unsquelch thresholds. It also includes a built-in  
timer to ensure fast and accurate signal detection and  
line noise rejection. Upon detection of two or more  
valid 10BASE-T or 100BASE-TX pulses on the line  
receive port, signal detect is indicated. The signal  
detect threshold is then lowered by about 40%. All  
adaptive circuits are released from their initial states  
and allowed to lock onto the incoming data. In  
100BASE-TX operation, signal detect is de-asserted  
when no signal is presented for a period of about  
1.2us. In 10BASE-T operation, signal detect is de-  
asserted whenever no Manchester data is received. In  
either case, the signal detect threshold will return to the  
squelched level whenever the signal detect indication  
is de-asserted. Signal detect is also used to control the  
operation of the clock/data recovery circuit to assure  
fast acquisition.  
Transmit high impedance mode is activated by  
setting the TXHIM bit in MII register MR16.12. In this  
mode of operation, the transmit UTP drivers are in a  
high impedance state and TX_CLK is tri-stated. A  
weak internal pull-up is enabled on TX_CLK. The  
receive circuitry remains fully operational. The  
default state of MR16.12 is a logic low for disabling  
the transmit high impedance mode. The transmitter  
is fully functional when MR16.12 is cleared.  
Analog Biasing and Supply Regulation  
Receive Clock Recovery  
The 78Q2120C requires no external component to  
generate on-chip bias voltages and currents. High  
accuracy is maintained through a closed-loop  
trimmed biasing network.  
In 100BASE-TX mode, the 125MHz receive clock is  
extracted using a digital DLL-based loop. When no  
receive signal is present, the CDR is directed to lock  
onto the 125MHz transmit serial clock. When signal  
detect is asserted, the CDR will use the received MLT-  
3 signal as the clock reference. The recovered clock is  
used to re-time the data signal and for conversion of  
the data to NRZ format.  
On-chip digital logic runs off an internal voltage  
regulator. Hence only a single Vcc supply is  
required to power-up the device. The on-chip  
regulator is not affected by the power-down mode.  
In 10BASE-T mode, the 10MHz receive clock is  
recovered digitally from the Manchester data using a  
Clock Selection  
DLL locked to the reference clock.  
When  
The 78Q2120C will use the on-chip crystal oscillator  
as the clock source if the CKIN pin is tied low. In this  
Manchester-coded preambles are detected, the  
Page: 2 of 35  
© 2009 Teridian Semiconductor Corporation Rev 1.3