FERRITE DEVICES
Technical information / Electrical features
In t e rm o d u la t io n p a ra m e t e rs
Base stations are using modulation signal thatTEMEX may not have.
In order to design and to provide data about intermodulation level 3, TEMEX is using a two tones
(channels) measurement.
The following conditions are used for the measurements:
• 1. Power on each channel: defined by the customer or minimum 25 Watt if not specified.
Frequencies of each two tones: taken at the center of the bandwidth
• 2. Forward intermodulation F1, P1, F2, P2, as input signals will give a forward
Intermodulation level IMP3
• 3. Reverse intermodulation F1, P1 in input, F2, P2 at the output, as input signals will
give a reverse intermodulation level IMP3
• 4. F1 and F2 are two tones with 20 MHz difference
Test set up
High band: 2090 MHz
1ton POWER
44.5 dBm
TX
Path
DIPLEXER
DIPLEXER
CABLE
LOAD
DUT
Low BAND: 2080 MHz
RX Path
3rd IMD Frequency: 2117.5 MHz
Spectrum Analyser
15-8
Vol. 1
SALES OFFICES : VIS IT OUR WEB S ITE AT
h tt p ://w w w .t e m ex.n e t