Series BS
4A to 600 Vac SIP Package
DC Control
Part Number
BS24D4A
BS24D4F
BS60D4A
Description
4A, 280 Vac
4A, 280 Vac
4A, 600 Vac
Part Number Explanation
BS
24
D
4
A
NOTES
1) Line Voltage: 24 = 280 Vac; 60 = 600 Vac
2) Switch Type: D = Zero-cross turn-on
3) Control Range: A = 3.0–10 Vdc for BS24D4A, 3.7–10 Vdc for
BS60D4A; F = 8–30 Vdc
FEATURES/BENEFITS
• Industry standard package
• High in-rush capabilities
• Low input current draw
• High dv/dt capability
DESCRIPTION
The BS 4-amp solid-state single inline (SIP) four-pin
relays are designed for mounting on a printed circuit
board. The BS relays can withstand very high current
overloads. The compact size and triac output make
the BS relay an excellent choice for switching medium-
power resistive loads.
APPLICATIONS
• Interface applications
• Vending machines
• Light/lamp control
• HVAC controls
APPROVALS
All models are UL recognized. VDE approved.
UL File Number: E128555.
MECHANICAL SPECIFICATION
1.70 (43.2)
±.02
±
0.01
.39 (10.2)
±
0.01
.98 (25.4)
- +
±.02
.19 (6.5)
.30
(7.63)
.49
±.001
.40
±.001
(12.7) (10.16)
WEIGHT: 0.7 oz. (20g)
Ø1
.20
±.001
(5.08)
.30
(7.62)
Figure 1 – BS relays; dimensions in inches (mm)
INPUT (CONTROL) SPECIFICATION
Min
Control Range
BS24D4A
BS24D4F
BS60D4A
Input Current Range
Must Turn-Off Voltage
BS24D4A
BS24D4F
BS60D4A
Input Resistance (Typical)
BS24D4A
BS24D4F
BS60D4A
© 2003 TELEDYNE RELAYS
Max
10
30
10
30
Units
Vdc
Vdc
Vdc
mAdc
BLOCK DIAGRAM
3
8
3.7
5
3+
1~
4–
Figure 2 – BS relays
0.8
0.8
1.5
Vdc
Vdc
Vdc
2~
330
1200
270
Ohms
Ohms
Ohms
BS 1
BS\032003\Q1
(800) 284-7007 • www.teledynerelays.com