SERIES 722
OUTLINE DIMENSIONS
SCHEMATIC DIAGRAM
CASE DETAIL
TERMINAL LOCATIONS AND PIN NUMBERS (REF. ONLY)
(Viewed from Terminals)
COIL B
.370
(9.40)
DIA. MAX.
.031 (0.79)
.003 (0.08)
.335
(8.51)
DIA. MAX.
.200 (5.08)
.010 (.25) DIA.
10
COIL A
722
9
6
1
4
.035 (0.89)
.010 (0.25)
COIL B
8
7
2
3
.280 (7.11) MAX.
.200 (5.08)
.010 (.25) DIA.
WIRE LEAD: .75 (19.05) MIN.
COIL A
36° 3° ꢀTY.
5
722D
SCHEMATICS ARE VIEWED FROM TERMINALS.
CONTACTS SHOWN IN POSITION RESULTING
WHEN COIL A LAST ENERGIZED.
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
+.002 (.05)
–.001 (.03)
.017 (.43)
DIA.
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 µsec or transfer in excess of
1 µsec.
2. “Typical” characteristics are based on available data and are best estimates. No on-
going verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. Unless otherwise specified, relays will be supplied with either gold-plated or solder-
coated leads.
5. The slash and characters appearing after the slash are not marked on the relay.
6.
Teledyne Part Numbering System for Commercial Relays
722 X M - 26 / S
Q
Q= Solder Coated Leads
G= Gold Plated Leads
(Notes 4 and 5)
Relay Series
Optional Ground Pin
(See Appendix )
S= 0.187" leads
(Note 5)
Pad Option
(See Appendix)
Coil Voltage
©2003 TELEDYNE RELAYS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
722 Page 98
722/1203/Q1