SERIAL INTERFACE ADAPTER FOR  
TC500 A/D CONVERTER FAMILY  
3
TC520A  
TC520A Initialization  
a range of AZ = INT = 256 counts to 65536 counts). (See  
Figure 2). The LOAD VALUE sets the number of counts for  
both the AZ and INT phases and directly affects resolution  
and speed of conversion. The greater the number of counts  
allowed for AZ and INT; the greater the A/D resolution, but  
the slower the conversion speed.  
Initialization of the TC520A consists of:  
(1) Power-On RESET of the TC500/520A (forcing the  
TC520A into an AZ phase).  
(2) Initializing the TC520A LOAD VALUE.  
ThetimeperiodrequiredfortheDINT phaseisafunction  
of the amount of voltage stored on the integrator during the  
INTphase, andthevalueofVREF. TheDINT phaseisinitiated  
by the TC520A immediately after the INT phase, and termi-  
nated when the TC5xx A/D converter changes the state of  
theCMPTRinputoftheTC520A(indicatingazerocrossing).  
In general, the maximum number of counts chosen for DINT  
is twice that of INT (with VREF chosen at VIN (max)/2).  
Choosing these values guarantees a full count (maximum  
resolution) during DINT when VIN = VIN(max).  
Power-On RESET  
The TC520A powers-up with A, B = 00 (IZ Phase),  
awaiting a high logic state on CMPTR, which must be  
initiated by forcing the TC520A into the AZ phase. This can  
be accomplished in one of two ways:  
(1) External hardware (processor or logic) can momen-  
tarily taking LOAD or CE low for a minimum of 100  
msec (tAZI); or  
The IZ phase is initiated immediately following the DINT  
phase maintained until the CMPTR input transitions high.  
This indicates the integrator is initialized and ready for  
anotherconversioncycle.Thisphasetypicallytakes 2msec.  
(2) A .01µF RESET capacitor can be connected from  
CE to VCC to generate a power-on pulse on CE.  
Load Value Initialization  
Serial Port Control Signals  
The LOAD VALUE is the preset value (high byte of the  
SYSCLK timing counter) which determines the number of  
counts allocated to the AZ and INT phases of conversion.  
ThisvaluecanbecalculatedusingtheTC520Aspreadsheet  
within the TC500 Design Spreadsheet software, or can be  
setup as shown in the following example:  
Communication to and from the TC520A is accom-  
plished over a 3 wire serial port. Data is clocked into DIN on  
therisingedgeofDCLK andclockedoutofDOUT onthefalling  
edge of DCLK. READ must be low to read from the serial port  
andcanbetakenhighatanytime, whichterminatestheread  
cycle, and releases DOUT to a high impedance state. Con-  
version data is shifted to the processor from DOUT in the  
following order: Overrange bit (which can also be used as  
the 17th data bit), Polarity bit, conversion data (MSB first).  
(1) Select VREF, TDINT  
Choose the TC5xx A/D converter reference voltage  
(VREF) to be half of the maximum A/D converter  
input voltage. For example, if VIN max = 2.5V;  
chooseVREF =1.75V. Thisforcesthemaximumde-  
integration time (TDINT) to be equal to twice the  
maximum integration time (TINT) ensuring a full  
APPLICATIONS  
TC500 Series A/D Converter Component Selection  
The TC500/500A/510/514 data sheet details the equa-  
tions necessary to calculate values for integration resistor  
(RINT) and capacitor (CINT); auto zero and reference capaci-  
torsCREF andCAZ andvoltagereferenceVREF. Allequations  
count (maximum resolution) during DINT  
.
(2) Calculate TINT  
applywhenusingtheTC520A,exceptintegrationtime(TINT  
)
The TC520A counter length is 16 bits (65536).  
Allowing the full 65536 counts for TDINT results in a  
maximum TINT = 65536/2 or 32768.  
andAutozerotime(TAZ)arefunctionsoftheSYSCLKperiod  
(timebase frequency and LOAD VALUE). TelCom offers a  
ready-to-use TC5xx A/D converter design tool on a 3 1/2  
inchdiskette(Windowsformat). TheTC500DesignSpread-  
sheet is an Excel-based spreadsheet that calculates values  
for all components as well as the TC520A LOAD VALUE. It  
alsocalculatesoverallconverterperformancesuchasnoise  
rejection, converter speed, etc. This software is included in  
the TC500EV hardware evaluation kit and is also available  
free of charge from your local TelCom representative.  
(3) Select SYSCLK Frequency  
SYSCLKfrequencydirectlyaffectsconversiontime.  
The faster the SYSCLK, the faster the conversion  
time. The upper limit SYSCLK frequency is deter-  
mined by the worst case delay of the TC500 com-  
parator (which for the TC500 and TC500A is  
3.2µsec). While a faster value for SYSCLK can be  
used, operation is optimized (error minimized) by  
choosing a SYSCLK period (1/SYSCLK frequency)  
that is greater than 3.2µsec. Choosing TSYSCLK  
=