ECONOMONITOR™ – 3-PIN SYSTEM SUPERVISOR
WITH POWER SUPPLY MONITOR AND WATCHDOG
TC32M
* Static-sensitive device. Unused devices must be stored in conductive
material. Protect devices from static discharge and static fields. Stresses
ABSOLUTE MAXIMUM RATINGS *
Supply Voltage ........................................................ +6.0V
Input Voltage, Any Pin........ (GND – 0.3V) to (VDD + 0.3V)
Operating Temperature Range
TC32MC Package ................................. 0°C to +70°C
TC32ME Package ............................ – 40°C to +85°C
Storage Temperature Range ................ – 65°C to +150°C
Lead Temperature (Soldering, 10 sec) ................. +300°C
above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. These are stress ratings only and functional
operation of the device at these or any other conditions above those
indicated in the operational sections of the specifications is not implied.
Exposure to Absolute Maximum Rating Conditions for extended periods
may affect device reliability.
RECOMMENDED OPERATING CONDITIONS, DC: TA = – 40°C to +85°C, unless otherwise specified.
Symbol
Parameter
Test Conditions
Min
Typ
Max
Unit
VDD
VIH
VIL
Supply Voltage
4.5
2.0
—
—
—
—
5.5
—
V
V
V
RS Input HIGH Level for PB
RS Input LOW Level for PB
0.3
ELECTRICAL CHARACTERISTICS, DC: VDD = 4.5V to 5.5V; TA = – 40°C to 85°C, unless otherwise specified.
Symbol
Parameter
Test Conditions
Min
Typ
Max
Unit
IIL
RS Input Leakage
RS Output Current
Operating Current
RS Strobe HIGH Level
RS Strobe LOW Level
RESET Threshold
– 1
2.0
—
10
50
—
—
—
+1
—
µA
mA
µA
V
IOL
VOL = 0.4V
Note 1
ICC
—
200
VSTH
VSTL
VRST
Figure 1
Figure 1
(VDD – 0.5)
2.00
—
(VDD – 1.5)
4.50
V
VDD Falling
4.25
V
(Note 2, Figure 3)
ELECTRICAL CHARACTERISTICS, CAPACITANCE: TA = 25°C, unless otherwise specified.
Symbol
Parameter
Test Conditions
Min
Typ
Max
Unit
CIN
Input Capacitance
Output Capacitance
—
—
—
—
5
7
pF
pF
COUT
ELECTRICAL CHARACTERISTICS, AC: TA = – 40°C to +85°C, VDD = 5V ±10%, unless otherwise specified.
Symbol
Parameter
Test Conditions
Min
Typ
Max
Unit
tRST
tST
RESET Active Time
Figure 2
Figure 1
Figure 1
Figure 3
500
500
500
—
700
—
900
—
msec
nsec
msec
nsec
RS STROBE Pulse Width
Watchdog Timeout Period
VDD Detect to RS LOW
tTD
700
—
900
100
tRPD
NOTES: 1. No output load.
2. All voltages referenced to ground.
5-4
TELCOM SEMICONDUCTOR, INC.