PRELIMINARY INFORMATION  
PRECISIONTEMPERATURE-TO-VOLTAGE  
CONVERTERS WITH SHUTDOWN MODE  
TC1023  
TC1024  
* Static-sensitive device. Unused devices must be stored in conductive  
material. Protect devices from static discharge and static fields. Stresses  
above those listed under Absolute Maximum Ratings may cause perma-  
nent damage to the device. These are stress ratings only and functional  
operation of the device at these or any other conditions above those  
indicated in the operational sections of the specifications is not implied.  
Exposure to Absolute Maximum Rating Conditions for extended periods  
may affect device reliability.  
ABSOLUTE MAXIMUM RATINGS *  
Supply Voltage ............................................................15V  
Input Voltage, Any Terminal ..............1.0 to (VCC +0.3V)  
Operating Temperature (TC1023)......... – 20°C to +100°C  
Operating Temperature (TC1024).........20°C to +125°C  
Storage Temperature ............................55°C to +150°C  
Lead Temperature (Soldering, 10 sec) ................. +300°C  
ELECTRICAL CHARACTERISTICS : TA = – 20°C to +125°C, VCC = 5V ±5%, GND = 0V, unless otherwise specified.  
Symbol  
Parameter  
Test Conditions  
Min  
Typ  
Max  
Unit  
VCC  
Supply Voltage (TC1023)  
(TC1024)  
2.2  
3.0  
12  
12  
V
IS  
Supply Current  
CE = VIL  
(Note 1)  
40  
60  
µA  
µA  
ICE  
Shutdown Current  
CE = VIH  
(Note 2)  
1
5
VIH  
VIL  
CE Input Logic HIGH Level  
CE Input Logic LOW Level  
CE Input Leakage Current  
Recovery Time from Shutdown  
2.0  
0.8  
+1  
V
V
ICE  
CE = VIH or VIL  
–1  
µA  
µsec  
tREC  
CE = step from VIH to VIL  
(Note 3)  
400  
VOUT  
VOUT Output Voltage (TC1024)  
TA = – 20°C and +125°C  
270  
1780  
1030  
mV  
VOUT Output Voltage (TC1023)  
TA = – 20°C and +100°C  
Circuit per Figure 1:  
R1 = 240kΩ  
– 230  
VSS = – 12V  
(Note 1)  
ISRC  
VOUT Output Source Current  
Accuracy at Room Temperature  
1.0  
+2  
mA  
TA = +25°C  
– 2  
°C  
(Note 4)  
Accuracy at Minimum Temperature  
Accuracy at Maximum Temperature  
TC1023: TA = – 20°C  
TC1024: TA = – 20°C  
(Note 4)  
– 4  
– 3  
+4  
+3  
°C  
°C  
TC1023: TA = +100°C  
TC1024: TA = +125°C  
(Note 4)  
Nonlinearity  
Note 5  
– 0.8  
80  
10  
+0.8  
°C  
µV/V  
mV/°C  
V
Line Regulation  
AV  
Average Slope of Output Voltage  
Maximum Output Voltage  
VOUTMAX  
TC1023: 2.2V VCC 12V  
TC1024: 3.0V VCC 12V  
(Note 1)  
VCC – 1.2  
NOTES: 1. VOUT outputs open circuited.  
2. VOUT is 0V through approximately 100kto ground when CE = VIH  
.
3. Recovery time is the period required for VOUT to rise from 0V (shutdown state) to the voltage corresponding to the measured  
temperature driving a 100pF capacitive load.  
4. Accuracy = Difference between calculated output voltage (10mV/°C x Device case temperature at specified temperature and power  
supply) and measured output voltage expressed in °C.  
5. Nonlinearity = deviation of output voltage versus temperature from the best-fit straight line over the device rated temperature range.  
TC1023/1024-05 6/12/97  