PRELIMINARY INFORMATION  
PRECISIONTEMPERATURE-  
TO -VOLTAGE CONVERTERS  
TC02  
TC03  
* Static-sensitive device. Unused devices must be stored in conductive  
material. Protect devices from static discharge and static fields. Stresses  
above those listed under Absolute Maximum Ratings may cause perma-  
nent damage to the device. These are stress ratings only and functional  
operation of the device at these or any other conditions above those  
indicated in the operational sections of the specifications is not implied.  
Exposure to Absolute Maximum Rating Conditions for extended periods  
may affect device reliability.  
ABSOLUTE MAXIMUM RATINGS *  
Supply Voltage ............................................................15V  
Input Voltage, Any Terminal ..............1.0 to (VCC +0.3V)  
Operating Temperature (TC02)............. – 20°C to +125°C  
Operating Temperature (TC03)............. – 20°C to +100°C  
Storage Temperature ............................55°C to +150°C  
Lead Temperature (Soldering, 10 sec)  
SOT-23B-3 ..................................................... +260°C  
TO-92-3 .......................................................... +300°C  
ELECTRICAL CHARACTERISTICS : TA = – 20°C to +125°C, VCC = 5V ±5%, unless otherwise specified.  
Symbol  
Parameter  
Test Conditions  
Min  
Typ  
Max  
Unit  
VCC  
VCC  
IS  
Supply Voltage (TC02)  
3.0  
2.2  
12  
12  
60  
1.0  
+2  
V
V
Supply Voltage (TC03)  
Supply Current  
Note 1  
40  
µA  
mA  
°C  
°C  
ISRC  
VOUT Output Source Current  
Accuracy at Room Temperature  
Accuracy at Minimum Temperature  
TA = 25°C (Note 2)  
– 2  
± 0.5  
TC02: TA = – 20°C  
TC03: TA = – 20°C  
(Note 2)  
– 7  
– 7  
± 0.5  
± 0.5  
+5  
+5  
Accuracy at Maximum Temperature  
TC02: TA = +125°C  
TC03: TA = +100°C  
– 3  
– 3  
+3  
+3  
°C  
(Note 2)  
Nonlinearity  
Note 3, 4  
– 0.8  
80  
10  
+0.8  
°C  
Line Regulation  
µV/V  
mV/°C  
AV  
Average Slope of Output Voltage  
Maximum Output Voltage  
VOUTMAX  
TC02: 3.0V VCC 12V  
TC03: 2.2V VCC 12V  
(Note 1)  
VCC – 1.2  
V
Notes: 1. VOUT outputs open circuited.  
2. Accuracy = Difference between calculated output voltage (10mV/°C x Device case temperature at specified temperature and power supply)  
and measured output voltage expressed in °C.  
3. Nonlinearity = deviation of output voltage versus temperature from the best-fit straight line over the device rated temperature range.  
4. Guaranteed by design.  
DETAILED DESCRIPTION  
OUTPUT STAGE  
A plot of output voltage versus temperature for both the  
TC02 and TC03 appears in Figure 1. The TC03 can be  
used with single power supply to measure temperatures  
from 0°C to 100°C. A pull-down resistor (R1 in Figure 2)  
must be added from VOUT to the negative power supply for  
measuring temperatures less than 0°C. The value of the  
resistor must be chosen to limit the maximum current  
pulled from the output to the negative supply to  
– 50µA (i.e. R1 = VSS/50µA).  
Both the TC02 and TC03 have Class A output stages  
capable of sourcing 1mA. These devices have a limited  
ability to drive heavy capacitive loads. Loads of 50pF (to  
ground) can be driven directly. For heavier loads, a 2k(or  
greater) resistor should be placed in series with the output  
for decoupling. If the TC02/03 is used in a noisy electrical  
environment, a 0.1µF bypass capacitor from VCC to GND is  
recommended.  
TC02/03-04 6/18/97  
2