1N4370A through 1N759A Series
ELECTRICAL CHARACTERISTICS (TA
= 25ºC unless
otherwise noted, VF = 1.5 V Max @ IF = 200mA for all types)
Symbol
VZ
Parameter
Reverse Zener Voltage @ IZT
Reverse Zener Current
IZT
ZZT
IZM
Maximum Zener Impedance @ IZT
Maximum DC Zener Current
Reverse Leakage Current @ VR
Reverse Voltage
IR
VR
IF
Forward Current
VF
Forward Voltage @ IF
ELECTRICAL CHARACTERISTICS (TA = 25ºC unless otherwise noted, VF = 1.5 V Max @ IF = 200mA for all types)
(Note 3.)
Zener Voltage
VZ (Volts)
Nom
IR @ VR = 1V
(Note 4.)
@ IZT
(Ω)
ZZT
ZM (Note 5.)
@ IZT
(mA)
I
TA = 25ºC
TA = 150ºC
Device
Device
Min
Max
(mA)
(Note 2.)
Marking
(µA)
(µA)
1N4370A
1N4271A
1N4372A
1N746A
1N747A
1N748A
1N749A
1N750A
1N751A
1N752A
1N753A
1N754A
1N755A
1N756A
1N757A
1N758A
1N759A
1N4370A
1N4271A
1N4372A
1N746A
1N747A
1N748A
1N749A
1N750A
1N751A
1N752A
1N753A
1N754A
1N755A
1N756A
1N757A
1N758A
1N759A
2.28
2.57
2.85
3.14
3.42
3.71
4.09
4.47
4.85
5.32
5.89
6.46
7.13
7.79
8.65
9.50
11.4
2.4
2.7
3
2.52
2.84
3.15
3.47
3.78
4.10
4.52
4.94
5.36
5.88
6.51
7.14
7.88
8.61
9.56
10.5
12.6
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
30
30
29
28
24
23
22
19
17
11
7
150
135
120
110
100
95
100
75
50
10
10
10
2
200
150
100
30
30
30
30
30
20
20
20
20
20
20
20
20
20
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
85
75
2
70
1
65
1
60
0.1
0.1
0.1
0.1
0.1
0.1
0.1
5
55
6
50
8
45
10
17
30
40
35
12
30
2. TOLERANCE AND TYPE NUMBER DESIGNATION (VZ)
The type numbers listed have a standard tolerance on the nominal zener voltage of ±5%.
3. ZENER VOLTAGE (VZ) MEASUREMENT
Nominal zener voltage is measured with the device junction in the thermal equilibrium at the lead temperature (TL) at 30°C
±1°C and 3/8” lead length.
4. ZENER IMPEDANCE (ZZ) DERIVATION
ZZT and ZZK are measured by dividing the AC voltage drop across the device by the AC current applied. The specified limits
are for IZ(AC) = 0.1 IZ(DC) with AC frequency = 60Hz.
5. MAXIMUM ZENER CURRENT RATINGS (IZM
)
Values shown are based on the JEDEC rating of 400mW where the actual zener voltage (VZ) is known at the operating
point, the zener current may be increased and is limited by the derating curve.
http://www.takcheong.com