HV5122/HV5222  
Electrical Characteristics (over recommended operating conditions unless noted)  
DC Characteristics  
Symbol  
Parameter  
Min  
Typ  
Max  
Units Conditions  
IDD  
VDD supply current  
15  
mA  
fCLK = 8MHz  
FDATA = 4MHz  
IDDQ  
Quiescent VDD supply current  
Off state output current  
100  
10  
µA  
µA  
All VIN = 0V  
IO(OFF)  
All outputs high  
All SWS parallel  
IIH  
High-level logic input current  
Low-level logic input current  
High-level output data out  
Low-level output voltage  
1
µA  
µA  
V
VIH = 12V  
IIL  
-1  
VIL = 0V  
VOH  
VOL  
VDD - 1.0V  
IDout = -100µA  
IHVout = +100mA  
HVOUT  
15.0  
1.0  
V
Data out  
V
IDout = +100µA  
VOC  
HVOUT Clamp Voltage  
-1.5  
V
IOL = -100mA  
AC Characteristics (VDD = 12V, TC = 25°C)  
Symbol  
fCLK  
Parameter  
Min  
Typ  
Max  
Units  
MHz  
ns  
Conditions  
Clock frequency  
8
tW  
Clock width high or low  
62  
25  
10  
tSU  
tH  
Data set-up time before clock falls  
Data hold time after clock falls  
Turn ON time, HVOUT from strobe  
Delay time clock to data high to low  
Delay time clock to data low to high  
ns  
ns  
tON  
tDHL  
tDLH  
500  
100  
100  
ns  
RL = 2Kto 200V  
CL = 15pF  
ns  
ns  
CL = 15pF  
Recommended Operating Conditions  
Symbol  
VDD  
Parameter  
Min  
Typ  
Max  
13.2  
225  
VDD  
2.0  
Units  
V
Logic supply voltage  
High voltage output  
High-level input voltage  
Low-level input voltage  
Clock frequency  
10.8  
-0.3  
12  
HVOUT  
VIH  
V
VDD - 2V  
0
V
VIL  
V
fCLK  
8
MHz  
°C  
°C  
Plastic  
-40  
-55  
+85  
+125  
TA  
Operating free-air temperature  
Ceramic  
Notes:  
Power-up sequence should be the following:  
1. Connect ground.  
2. Apply VDD  
.
3. Connect all inputs to a known state.  
Power-down sequence should be the reverse of the above.  