HV2221
AC Electrical Characteristics
(Over recommended operating conditions: VDD = +5.0V, tR = tF ≤5.0ns, 50% duty cycle, VPP = +40V, VNN = -200V, CLOAD = 20pF, unless otherwise specified)
0OC
Max
+25OC
+70OC
Sym Parameter
Units Conditions
Min
Min
Typ
-
Max
Min
Max
tSD
Set up time before LE rises
-
-
-
-
-
-
-
-
-
-
-
25
-
-
-
-
-
-
-
-
-
-
-
-
ns
ns
---
-
-
56
12
78
30
-
-
-
VDD = 3.0V
VDD = 5.0V
VDD = 3.0V
VDD = 5.0V
---
tWLE
Time width of LE
-
-
-
-
-
-
-
-
tDO
tWCL
tSU
Clock delay time to data out
Time width of CLR
ns
ns
-
-
-
-
-
55
-
-
-
-
-
21
7.0
-
-
-
-
-
VDD = 3.0V
Set up time data to clock
Hold time data from clock
Clock frequency
ns
-
VDD = 5.0V
VDD = 3.0 or 5.0V
VDD = 3.0V
VDD = 5.0V
---
tH
2.0
-
2.0
-
-
2.0
-
ns
-
8.0
fCLK
MHz
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
20
50
5.0
5.0
20
20
20
-
-
-
-
-
-
-
-
tR, tF
tON
Clock rise and fall times
Turn on time
50
5.0
5.0
20
20
20
50
5.0
5.0
20
20
20
ns
μs
V
= -100V,
RSLOIGAD = 10kΩ to GND
tOFF
Turn off time
VPP = +40V, VNN = -200V
dv/dt Maximum VSIG slew rate
V/ns VPP = +50V, VNN = -190V
VPP = +15V, VNN = -225V
f = 5.0MHz, VOFFSET = -15V,
-30
-58
-
-
-30
-58
-60
-
-33
-
-30
-58
-
-
1.0KΩ/15pF load
KO
Off isolation
dB
f = 5.0MHz, VOFFSET = -15V,
50Ω load
-
-
-
-
-
-
-
-
-
f = 5.0MHz, VOFFSET = -15V,
50Ω load
KCR
IID
Switch crosstalk
dB
Output switch isolation diode
current
300ns pulse width,
2.0% duty cycle
-
300
300
-
300
mA
CSG(OFF) Off capacitance SW to GND
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
18
70
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
pF
pF
f = 1.0MHz, VOFFSET = -15V
f = 1.0MHz, VOFFSET = -15V
CSG(ON) On capacitance SW to GND
+VSPK
-VSPK
59
V
PP = +40V, VNN = -200V,
RLOAD = 50Ω
115
71
+VSPK
VPP = +50V, VNN = -190V,
RLOAD = 50Ω
Output voltage spike
-VSPK
mV
pC
115
56
+VSPK
-VSPK
VPP = +15V, VNN = -225V,
RLOAD = 50Ω
115
V
PP = +40V, VNN = -200V,
-
-
-
-
-
-
-
-
-
1950
1890
2110
-
-
-
-
-
-
-
-
-
VSIG = 0V
VPP = +50V, VNN = -190V,
VSIG = 0V
QC
Charge injection
VPP = +15V, VNN = -225V,
VSIG = 0V
4