HV220/HV20220/HV20320
Electrical Characteristics
AC Characteristics (over operating conditions VDD = 5V, unless otherwise noted)
0°C
+25°C
+70°C
max
Characteristics
Sym
Units
TestConditions
min
150
150
max
min
150
150
typ*
max
min
150
150
Set Up Time Before LE Rises
Time Width of LE
tSD
tWLE
tDO
ns
ns
Clock Delay Time to Data Out
Time Width of CL
150
150
150
ns
tWCL
tSU
150
15
150
15
150
20
ns
Set Up Time Data to Clock
Hold Time Data from Clock
ClockFreq
8.0
ns
th
35
35
35
ns
fCLK
5.0
5.0
5.0
MHz
50% duty cycle
fDATA =fCLK/2
Clock Rise and Fall Times
tr, tf
50
50
50
ns
Turn On Time
tON
5.0
5.0
5.0
µs
VSIG = VPP -10V,
RL = 10KΩ
Turn Off Time
tOFF
dv/dt
KO
5.0
20
20
20
5.0
20
20
20
5.0
20
20
20
µs
VSIG = VPP -10V,
RL = 10KΩ
V
PP = 160V,
VNN = -40V
Maximum VSIG Slew Rate
Off Isolation
V/ns
VPP = 100V,
VNN = -100V
V
PP = 40V,
VNN = -160V
-30
-58
-60
-30
-58
-60
-33
-70
-30
-58
-60
dB
dB
dB
mA
f = 5MHz,
1KΩ//15pF load
f = 5MHz,
50Ω load
SwitchCrosstalk
KCR
IID
f = 5MHz,
50Ω load
Output Switch Isolation
DiodeCurrent
300
300
300
300nspulsewidth,
2.0% duty cycle
Off Capacitance SW to GND
On Capacitance SW to GND
CSG(OFF)
CSG(ON)
5.0
25
17
50
5.0
25
12
38
17
50
5.0
25
17
50
pF
pF
0V, 1MHz
0V, 1MHz
Electrical Characteristics
AC Characteristics (over operating conditions VDD = 5V, unless otherwise noted)
+25°C
Units
Characteristics
Sym
Test Conditions
min
typ*
max
Output Voltage Spike
+VSPK
150
V
PP = 40V, VNN = -160V, RL = 50Ω
– VSPK
+VSPK
– VSPK
+VSPK
– VSPK
150
150
150
150
150
mV
VPP = 100V, VNN = -100V, RL = 50Ω
VPP = 160V, VNN = -40V, RL = 50Ω
Charge Injection
820
600
350
VPP = 40V, VNN = -160V, VSIG = 0V
VPP = 100V, VNN = -100V, VSIG = 0V
Q
pC
V
PP = 160V, VNN = -40V, VSIG = 0V
* Typical values are only for HV202/HV203
B021706