SPARKLE POWER INC.
FSP030/040‐DxAN3 Series AC‐DC POWER SUPPLY
Specifications:
Model
FSP030‐DRAN3
9V
FSP030‐DHAN3
12V
FSP036‐DHAN3
12V
FSP040‐DRAN3
9V
FSP040‐DHAN3
12V
FSP040‐DAAN3
24V
Rated Voltage
Current
0 ~ 3.33
30W
0 ~ 2.5A
30W
0 ~ 3.0A
36W
0 ~ 4.44A
40W
0 ~3.33A
40W
0 ~ 1.67A
40W
Watts
Voltage Regulation
Overshoot
±5%
±10%
±10%
Dynamic Load Change
Ripple & Noise (Max.)
Turn on Time (Max.)
Rise Time (Max.)
Hold up Time (Min.)
Output
150mVp‐p
150mVp‐p
150mVp‐p
150mVp‐p
150mVp‐p
120mVp‐p
3Sec
30ms
8ms
10ms
8ms
8ms
10ms
5ms
≥87.7%
DOE VI & COC
tier 2
≥87.7%
DOE VI & COC
tier 2
≥88.3%
DOE VI & COC
tier 2
≥88.59%
DOE VI & COC
tier 2E
≥88.59%
DOE VI & COC
tier 2
≥88.59%
DOE VI & COC
tier 2
Efficiency (Average)
Voltage Range
Frequency Range
Current (Max.)
90 ~ 264Vac
47 ~ 63Hz(±1Hz)
1A
1.2A
1.2A
1.2A
1.4A
1.4A
Input
58.5A @110Vac 45.5A @115Vac 52.0A @115Vac
127A@220Vac 98.0A@230Vac 118A@230Vac
50.0A @110Vac
95A@220Vac
58A @115Vac
124A@230Vac
Inrush Current (cold start, full load,25°C)
105A@220Vac
Leakage Current (Max.)
No Load Power Consumption
Short Circuit Protection
Over Current Protection
Over Voltage Protection
Over Temperature Protection
Safety Approvals
0.25mA at 264VAC/50Hz
0.075W
output shut down and auto‐recovery after Fault condition removed
output shut down and auto‐recovery after Fault condition removed
output shut down at 160% of voltage and recovery after AC reset
output shut down at abnormal temperature and recovery after AC reset
CB,UL/cUL, TUV
Protection
EMI/EMC
FCC Part 15 Class B, EMC
Safety &
Compliance
RoHS
2011/65/EU; (EU) 2015/863
Hi Pot
Input to output 1.5KV for 1 minute
Insulation Resistance
Input to Output at 500Vdc ≥20MΩ
0~40⁰C/20~80% (safety)
40 to 70⁰C Linearly de‐rating, need to check safety with system
Operating Temperature/ Humidity
Storage Temperature/ Humidity
‐20~80⁰C/10~90%
(1)Non‐operating, 0.01g2/Hz at 5Hz,slopping to 0.02g2/Hz at 20Hz,
And maintain 0.02g2/Hz from 20Hz ~ 500Hz
(2)PSD=3.13grms, 15 minutes/axis
Environment
Vibration
(3)Vibration duration:15minutes
(4)Vibration waveform: Random
(5)Force Direction X,Y,Z
Dimension ((L*W*H)
Adapter Weight (Typical)
MTBF
110 x 50 x 32 mm
280g
Other
Note
Above 300K hours, Telcordia SR‐332 (25⁰C)
Contact SPI sales for further information
www.sparklepower.com
Tel: 1‐408‐519‐8888/1‐626‐839‐7180
E‐Mail: sparkle@sparklepower.com
2