CY28410  
Byte 6: Control Register 6 (continued)  
Bit  
@Pup  
Name  
Description  
2
Externally  
selected  
CPUT/C  
FS_C. Reflects the value of the FS_C pin sampled on power-up  
0 = FS_C was low during VTT_PWRGD# assertion  
1
0
Externally  
selected  
CPUT/C  
CPUT/C  
FS_B. Reflects the value of the FS_B pin sampled on power-up  
0 = FS_B was low during VTT_PWRGD# assertion  
Externally  
selected  
FS_A. Reflects the value of the FS_A pin sampled on power-up  
0 = FS_A was low during VTT_PWRGD# assertion  
Byte 7: Vendor ID  
Bit  
7
@Pup  
Name  
Revision Code Bit 3  
Revision Code Bit 2  
Revision Code Bit 1  
Revision Code Bit 0  
Vendor ID Bit 3  
Description  
Revision Code Bit 3  
Revision Code Bit 2  
Revision Code Bit 1  
Revision Code Bit 0  
Vendor ID Bit 3  
0
0
1
0
1
0
0
0
6
5
4
3
2
Vendor ID Bit 2  
Vendor ID Bit 2  
1
Vendor ID Bit 1  
Vendor ID Bit 1  
0
Vendor ID Bit 0  
Vendor ID Bit 0  
Crystal Recommendations  
Crystal Loading  
The CY28410 requires a Parallel Resonance Crystal. Substi-  
tuting a series resonance crystal will cause the CY28410 to  
operate at the wrong frequency and \violate the ppm specifi-  
cation. For most applications there is a 300ppm frequency shift  
between series and parallel crystals due to incorrect loading.  
Crystal loading plays a critical role in achieving low ppm perfor-  
mance. To realize low ppm performance, the total capacitance  
the crystal will see must be considered to calculate the appro-  
priate capacitive loading (CL).  
The following diagram shows a typical crystal configuration  
using the two trim capacitors. An important clarification for the  
following discussion is that the trim capacitors are in series  
with the crystal not parallel. It’s a common misconception that  
load capacitors are in parallel with the crystal and should be  
approximately equal to the load capacitance of the crystal.  
This is not true.  
Table 5. Crystal Recommendations  
Frequency  
(Fund)  
Drive  
(max.)  
ShuntCap Motional  
(max.)  
Tolerance  
(max.)  
Stability  
(max.)  
Aging  
(max.)  
Cut  
Loading Load Cap  
Parallel 20 pF  
(max.)  
14.31818 MHz  
AT  
0.1 mW  
5 pF  
0.016 pF  
35 ppm  
30 ppm  
5 ppm  
Rev 1.0,November 21, 2006  