SL74LS05
MAXIMUM RATINGS*
Symbol
Parameter
Value
7.0
Unit
V
VCC
Supply Voltage
Input Voltage
Output Voltage
V
IN
7.0
V
VOUT
Tstg
7.0
V
Storage Temperature Range
-65 to +150
°C
*Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
4.75
2.0
Max
Unit
V
VCC
Supply Voltage
5.25
V
IH
High Level Input Voltage
Low Level Input Voltage
High Level Output Voltage
Low Level Output Current
V
V
IL
0.8
5.5
8.0
+70
V
VOH
IOL
TA
V
mA
°C
Ambient Temperature Range
0
DC ELECTRICAL CHARACTERISTICS over full operating conditions
Guaranteed Limit
Symbol
Parameter
Input Clamp Voltage
Test Conditions
VCC = min, IIN = -18 mA
VCC = min, VOH =max
VCC = min, IOL = 4 mA
VCC = min, IOL = 8 mA
Min
Max
-1.5
0.1
0.4
0.5
20
Unit
V
V
IK
IOH
High Level Output Current
Low Level Output Voltage
mA
V
VOL
IIH
High Level Input Current
VCC = max, V = 2.7 V
mA
mA
mA
mA
IN
VCC = max, V = 7.0 V
0.1
-0.4
2.4
IN
IIL
Low Level Input Current
Supply Current
VCC = max, V = 0.4 V
IN
ICC
VCC = max
Total with
outputs high
Total with
6.6
outputs low
System Logic
Semiconductor
SLS