GPFC160 Commercial 160 Watt Single Output
Output
Output
Model
Output No.
Output
5.1 V
12 V
15 V
24 V
28 V
48 V
Maximum (A)
Peak (B)
OVP Setpoint
6.2 ± 0.6 V
14 ± 1.1 V
18.5 ± 1.5 V
28 ± 2.5 V
34 ± 2.8 V
55 ± 4.0 V
Ripple & Noise
GPFC160-5
GPFC160-12
GPFC160-15
GPFC160-24
GPFC160-28
GPFC160-48
1
1
1
1
1
1
25 A
11.7 A
9.3 A
5.8 A
5 A
31.3 A
13.3 A
10.7 A
6.7 A
1%
1%
1%
1%
1%
1%
5.7 A
2.9 A
3.4 A
A. Output rating with unrestricted convection cooling.
B. Output rating with 26 cfm airflow.
GPFC160 MECHANICAL SPECIFICATIONS
Environmental
Operating
Non-operating
Specification
Temperature (A)
Humidity (A)
Shock (B)
0 to 50oC
0 to 95% RH
20 gpk
-40 to +85oC
0 to 95% RH
40 gpk
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power. Derated output current and total output power by
2.5% per 50ºC.
Altitude
-500 to 10,000 ft
1.5 grms, 0.003 g2/Hz
-500 to 40,000 ft
5 grms, 0.026 g2/Hz
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes.Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
total 6 shocks.
Vibration (C)
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
63