GP1A073LCS
●
Recommended Installation Hole drawing
1) We recommend to fix the product at punching side on the fixing plate (metal plate).
2) Please decide the final dimensions at your side after confirmation by the actual applications, Because
mounting efficiency and mounted stabilization are dependent on mounting hole corner curve and punched
state.
3) Tolerance shall be 0.1mm
±
Normal type
8−R0.1
8−R0.1
8−R0.1
7.7
7.5
Plate thickness : 1.2mm
7.5
Plate thickness : 1mm
Plate thickness : 1.6mm
Reverse-insertion prevention type
12−R0.1
12−R0.1
12−R0.1
2.4
2.4
2.4
2.4
2.4
2.4
7.7
Plate thickness : 1.6mm
7.5
Plate thickness : 1.2mm
7.5
Plate thickness : 1mm
Sheet No.: D3-A04701EN
7